Sleep Mode Recommendations

Sleep Mode is recommended when the unit will not have any usage for a period of time over 3 hours. This increases
the life of the machine and reduces energy consumption.
A wake time must be programmed to return the unit to normal operation. It is recommended that the unit be
programmed to wakeup approximately 20 minutes before product is needed. For ambient temperature higher than
o
75
F, the times may increase as the ambient temperatures increases.

Viscosity Setting

The lowest possible viscosity settings are recommended to achieve desired drink quality. In most typical
installations, using sugar-based syrup allows the viscosity to be set slightly higher. Diet syrups freeze much more
readily than sugar based syrups, so the viscosity should be set lower for diet products.
This increased viscosity is achieved by freezing the product in the cylinder to a lower temperature, thereby
increasing ice crystal size and growth. As the ice crystal size increases, there is a potential for product quality to
diminish.