Megger Limited
Archcliffe Road, Dover
Kent CT17 9EN
England
T +44 (0)1 304 502101
F +44 (0)1 304 207342
E uksales@megger.com
Megger
4271 Bronze Way, Dallas,
Texas 75237-1019
USA
T +1 214 333 3201
T +1 800 723 2861 (USA only)
F +1 214 331 7399
E ussales@megger.co
Megger
Z.A. Du Buisson de la Couldre
23 rue Eugène Henaff
78190 TRAPPES
France
T +33 (0)1.30.16.08.90
F +33 (0)1.34.61.23.77
E infos@megger.com
Megger Pty Limited
Unit 26 9 Hudson Avenue
Castle Hill
Sydney NSW 2125
Australia
T +61 (0)2 9659 200
F +61 (0)2 9659 2201
E ausales@megger.com
Megger Limited
110 Milner Avenue Unit 1
Scarborough Ontario M1S 3R2
Canada
T +1 416 298 9688 (Canada only)
T +1 416 298 6770
F +1 416 298 0848
E casales@megger.com
Megger products are distributed in 146 countries worldwide.
This instrument is manufactured in the USA.
The company reserves the right to change the
specification or design without prior notice.
Megger is a registered trademark
Part No. 6172-967_en_V03 Printed in England 1006
www.megger.com
M
ICLAMP USER GUIDE
These safety warnings are provided to ensure the safety of personnel and proper operation of the
instrument.
I
I
I
I
I
I
I
I
I
I
Users of this equipment and/or their employers are reminded that National Health and Safety
Legislation requires them to carry out valid risk assessments of all electrical work so as to
identify potential sources of electrical danger and risk of electrical injury such as inadvertent short
circuits. Where the assessments show that the risk is significant then the use of fused test leads
may be appropriate.
The safety warnings provided in this document are indicative of safe practice and shall not be con-
sidered exhaustive. Additionally, they are not intended to replace local safety procedures where
the instrument is being used.
Symbols used on the ICLAMP are:
G
t
c
G
Safety Warnings
Safety warnings and precautions must be read and understood before the ICLAMP is used.
They must be observed during use.
Do not leave the ICLAMP connected to the system under test when not in use.
Do not touch circuit connections and exposed metalwork of the installation or equipment under
test.
Do not use the ICLAMP or connect it to any external system if it shows any visible signs of
damage or if it has been stored for prolonged periods in unfavourable conditions.
Do not use the ICLAMP or connect it to any external system if the casing is open or any parts of
the case are missing.
Do not use the ICLAMP or connect it to any external system if the ICLAMP lead is damaged in
any way.
Do not use the ICLAMP on live electrical conductors.
Always connect the ICLAMP to the DET instrument before clamping it around the item being
tested.
Always inspect the DET instrument, ICLAMP and connection cable prior to every use. Replace
any defective parts immediately.
Always use extreme caution when clamping around bare conductors: under fault conditions,
potentially high voltages and currents may be present and may pose a shock hazard.
NOTE: THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND
COMPETENT PERSONS.
Caution: refer to accompanying notes
Equipment protected throughout by Double Insulation (Class II)
Equipment complies with current EU directives