FirstCheck+ 1000, 2000, 3000 & 5000

Instrument Menu

General Instrument navigation
In the function menu use the UP and DOWN keys to find the function you require and press the ENTER key
to access that functions option
Data Logging - Files
FirstCheck+ versions 2000, 3000 and 5000 automatically logs the instruments gas readings every second
while the instrument displays real-time readings. Each reading is stored with a date and time stamp. An 8
Megabyte memory is set aside for data logging. However, when the memory is full the instrument will
overwrite previously stored data. FirstCheck+ does contain a memory full alarm that prompts the user to
download stored data (see „Instrument Menu‟).
Data Logging - Zones
To help keep track of Data logged files, FirstCheck+ allows an 8 digit identifier called Zones that can be
attached to each data file. A list of up to 199 Zones can be created on the 1stPC software and then
downloaded to the FirstCheck+ instrument. Once a Zone is selected on the instrument, all data files will
include that Zone name in the files header detail. To avoid long download times Ion Science recommends
downloading data on a daily basis. The FirstCheck+ has a default Zone called Zone 0. Unless specified, all
readings will automatically be stored in this Zone.

Zone Selection

Enter the FirstCheck+'s function menu and enter the ZONE SELECT icon. Use the UP & DOWN keys to
change the pre-programmed Zone name, then press the ENTER key to select it. A tick will appear to
confirm the selection. Press the ESC key to return to the Main Menu. Any logged data will now contain the
selected Zone name.
Viewing Data
Data must be downloaded from FirstCheck+ to a PC to be viewed.
st
(„1
PC Software‟)
PC Communication
To begin communication between the instrument and the computer
select the Data Transfer option. When the instrument is
communicating with a PC a  will be displayed in the data transfer
symbol and when not communicating an X will be shown. Place the instrument on its side with its infrared
window a few inches from the PC's IRDA . To exit the data transfer option press the ESC key.

Alarm

When in Survey mode, all upper and lower sensor alarm levels can be set by the user to
indicate particular levels of detection specific to the users need‟s. Both alarms give an audible
and visible output (flashing LED) but with increased urgency with the upper alarm. An alarm
state will occur when the preset alarm levels are exceeded; the alarms can be reset by
pressing the ENTER key but will continue to trigger if the alarm level is still exceeded.
Please note: It is the user's responsibility to respond appropriately to an alarm condition
press the ENTER key again. Use the UP and DOWN keys to change the alarm setting. These alarms can also
be easily adjusted on a PC via the Gas Table in the 1stPC software, that is then downloaded to the
instrument via the IRDA link. Please note that for safety reasons the lower alarm cannot be set above the
upper alarm.
.
(FirstCheck+ 2000, 3000 & 5000)
(FirstCheck+ 2000, 3000 & 5000)
(FirstCheck+ 1000, 2000, 3000 & 5000)
Upper and Lower alarm levels in survey mode are easy to adjust on the
instrument. Select the Alarm symbols (as above) and press the ENTER key.
Use the UP and DOWN keys to select the Alarm graphic in the function menu
and press ENTER. Select the alarm you wish to adjust (Upper or Lower) and
Page 16 of 45
Ion Science Ltd
(FirstCheck+ 2000, 3000, & 5000)
(FirstCheck+ 2000, 3000, & 5000)
Ion Science Ltd
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Firstcheck+ 3000Firstcheck+ 1000Firstcheck+ 5000

Table of Contents