Any trip can be initiated by writing the relevant trip number to Pr 10.38. If any trips
shown as user trips are initiated the trip string is "txxx", where xxx is the trip number.
Trips can be reset after 1.0s if the cause of the trip has been rectified.
A full list of drive trips can be found in the Unidrive SP User Guide.
Table 7.1 Trip codes
Trip
SMARTCARD trip: Solutions Modules fitted are different between source drive
C.Optn
and destination drive
1. Ensure correct Solutions Modules are fitted
180
2. Ensure Solutions Modules are in the same Solutions Module slot
3. Reset the drive
Solutions Module trip: Solutions Module has failed to recognise that the drive
SL.rtd
operating mode has changed
1. Ensure Solutions Module is fitted correctly
215
2. Contact the supplier of the Solutions Module
SLX.dF
Solutions Module slot X trip: Solutions Module type fitted in slot X changed
204,209,
Save parameters and reset the drive
214
Solutions Module slot X trip: Error detected with Solutions Module, where X is
SLX.Er
the slot number
If the drive trips SLX.Er, Pr x.50 will display the error code. An explanation of all error
202, 207,
codes is given below:
212
Pr x.50
0
1
2*
11
74
*This trip can be enabled/disabled by Pr x.17.
When the drive is reset Pr x.50 is cleared.
SLX.HF
Solutions Module slot X trip: Solutions Module X hardware fault
1. Ensure Solutions Module is fitted correctly
200,205,
210
2. Contact the supplier of the Solutions Module
SLX.nF
Solutions Module slot X trip: Solutions Module has been removed
1. If the Solutions Module has been purposely removed from the drive, save
parameters and reset the drive.
203,208,
2. Ensure Solutions Module is fitted correctly
213
3. Replace Solutions Module
4. Save parameters and reset drive
The SM-Resolver will only provide speed and position feedback when it is selected as
NOTE
the source of the drive speed/position feedback. Hence the SM-Resolver does not
function when the drive is operating in open-loop mode.
32
Fault description
No errors
Supply short circuit
The wire break detection looks at the SIN and COS signals and expects one signal
to be above the high threshold when the other is below the low threshold, or for
both signals to be in-between the threshold values. If the above conditions are not
satisfied, an error code 2 is produced.
The number of poles of the resolver is greater than 2, but is different to the number
of poles of the motor.
Solutions Module overtemperature.