Operation

Loopback test (using the Master Unit):

10Base-T Cable Test

Plug one end of the cable under test into the source RJ45 socket,
(marked with the p arrow), and the other end of the cable under
test into the second, receiving RJ45 socket.
Switch the Master Unit on. The LED's will start to scan in sequence
if the Auto/Manual switch is set to Auto mode or, the LED will light
on pin 1 if the Auto/Manual switch is set to Manual mode.
Note: Ensure the battery has sufficient charge or inaccurate results may be
obtained.
Use the 'Auto / Manual' switch to select the required scan method.
When scanning, the upper and lower LED indicators will illuminate
simultaneously.
Observe the LED displays. It shows the status of the pin
configuration of the cable under test. If you fail to read the result in
the first LED scan, in 'Auto' mode the scan will repeat continuously.
If 'Manual mode' is selected, press the test switch to scan the pins
one by one. Please refer to picture 1 below.