Dialight WOSU22BG2 User Manual

Wireless occupancy sensor

Advertisement

Quick Links

9100-127-2989-99 REV B
Wireless Occupancy Sensor
Wireless Occupancy
Sensor
User Guide
This Manual covers both the Wide angle and the Narrow long range
occupancy sensor.
Dialight Part Numbers described here-in are:
WOSU22BG2
Wide angle
WOSU12BG2
Long Range
Wide optic version
Long Range Version
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
1

Advertisement

Table of Contents
loading

Summary of Contents for Dialight WOSU22BG2

  • Page 1 This Manual covers both the Wide angle and the Narrow long range occupancy sensor. Dialight Part Numbers described here-in are: WOSU22BG2 Wide angle WOSU12BG2 Long Range Wide optic version Long Range Version 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 2: Table Of Contents

    How to Mount ..................................... 12 Long Range Sensor Wall Mount ..............................13 How to Mount ..................................... 14 Troubleshooting ..................................15 Troubleshooting Continued: ............................... 16 Troubleshooting Continued: ............................... 17 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 3: Introduction

    Keep These Instructions READ AND FOLLOW ALL SAFETY INSTRUCTIONS Welcome to the Dialight Wireless Occupancy Sensor user manual. This product allows you to customize your entire lighting network using independent Occupancy Sensors throughout your facility by turning lights on when occupancy has been detected.
  • Page 4: Wireless Occupancy Sensor Gen 2 Specifications

    Push and hold for 5 seconds. Sensor will double blink while trying to join a gateway, Sensor will stop blinking if it doesn’t join a gateway within 30 minutes. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 5: Unboxing

    Qty 3 – #8-32 Machine Screws Qty 2 – Lithium “AA” Batteries Qty 2 – Battery Clips Take Note of the following information: Dialight Catalog Number: Date Code: Install Date: 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 6: Sensor Overview

    9100-127-2989-99 REV B Sensor Overview Mounting Plate with Twist Lock LED Indicators Sensor Lens 3 Mounting Holes Sensor Housing Front View 2.38” 5.0” 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 7: Battery Installation/Removal

    To remove the sensor, twist sensor cover counterclockwise to unlock it from the back plate. Once cover has been removed you’re now ready to add or remove the batteries. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 8: Sensor Lights

    NOTE: Turning switch to on will cause increase current draw to the batteries and will shorten life based on the amount of motion detection. LED On/Off Switch 3. Twist close the sensor back on to the mounting plate. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 9 Only replace batteries with same size and type. ____________________________________________________________________________________ Red LED3 Low Bat blinking twice in a second means sensor is looking for a network and battery voltage is under 2.7V. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 10: Commissioning

    1. When the green LED blinks twice a second on the sensor, the sensor is ready to be discovered/commissioned. 2. Use a Dialight gateway to discover the sensor. (Please refer to the gateway owner’s manual for further instructions under the devices page.) 3.
  • Page 11: Wide Angle Sensor Ceiling Mount

    2.7 meters or 8.8 feet from the floor. Sensor should be mounted 6ft away from any open air vent or strong air supply openings. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 12: How To Mount

    4. Use the three provided screws and secure sensor to the ceiling. 5. Attach and lock the sensor to the mounting plate. Ceiling Mounting Plate Screws Sensor 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 13: Long Range Sensor Wall Mount

    The long range sensor is best used as a wall mounted sensor. The recommended install for this sensor is 3.2 meters or 10.5 feet from the floor. Avoid placing sensors where obstacles can block the sensor’s line of sight. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 14: How To Mount

    4. Use the three provided screws and secure sensor to the wall. 5. Attach and lock the sensor to the mounting plate. Wall Sensor Screws Mounting Plate 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 15: Troubleshooting

    9100-127-2989-99 REV B Troubleshooting Sensor is not discovered by the gateway. NOTE: This section requires the Dialight Gateway and to be connected to a computer using the GUI interface. Steps to solve: 1. On the gateway web page verify that discovery is turned on.
  • Page 16: Troubleshooting Continued

    Continue to step 2. i. If it does not blink for motion. j. Confirm the led SW2 is set to on. k. If not then replace the sensor 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...
  • Page 17: Troubleshooting Continued

    14. If none show motion present then this sensor is likely part of a different gateway network. Follow steps in this manual to remove the sensor from a different gateway. 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com...