5.6

Flue gas output and air input

For the installation of the flue gas output and air input material, we
refer to the enclosed basic manual, or contact the manufacturer of
the appropriate flue gas output and air input equipment for
extensive technical information and specific assembly instructions.
Make sure that the spigot and socket joint of the flue gas
output and air input materials seal effectively and will not
come loose. Not properly attaching the flue gas output and the
air input can lead to dangerous situations or physical injury.
Check all parts which transport flue gas or air for air tightness.
5.6.1
Concentric connection 60/100
The boiler is fitted with a flue gas adapter suitable for connecting to
a concentric flue gas extractor system with a diameter of 60/100.
Fit the concentric pipe for the air supply and burning gas extraction in the
adapter. The built in gaskets ensure there is an air tight seal.
5.6.2
Concentric connection 80/125
If required, the flue gas adapter 60/100 can be replaced by a version
for a flue gas extractor system with a 80/125 diameter.
1.
Carefully follow the instruction as provided with the adapter set 80/125.
2.
Fit the concentric pipe for the air supply and burning gas extraction in the adapter. The
built in gaskets ensure there is an air tight seal.
5.6.3
Parallel connection 80/80
If required, the flue gas adapter 60/100 can be replaced by a version
for a parallel flue gas extraction system (2 pipes) with a 80 mm diameter.
1.
Carefully follow the instruction as provided with the adapter set 80.
2.
Fit the pipes for the air supply and burn gas extraction in the input and output of the
unit. The built in gaskets ensure there is an air tight seal.
5.6.4
Materials to be used:
Unit
Materials
category
C13
Feedthrough
Other parts
C33
Feedthrough
Feedthrough at the Prefab chimney
Other parts
C43
All materials
At the CLV system
C53
Inlet roster
Other parts and exhaust hood
C63
All materials and feedthrough
Main channel
Other parts
C83
Inlet roster
C93
All materials
Daikin Europe NV
Supplier/Test standard
Daikin
Gastec QA or Daikin
Daikin
Gastec QA, Daikin or third
parties
In accordance to applicable
national or local legislation
Gastec QA or Daikin
Gastec QA
Daikin
Gastec QA or Daikin
Gastec QA
Gastec QA
Gastec QA or Daikin
Daikin
Gastec QA or Daikin