3.5.

External Public Address System and external music source wiring

UNICONT DTS-100 System provides the possibility of connecting of external
Public Address system. XS5 (P.A.) terminal group is assigned to wire the key
telephone system to the corresponding sockets of Public Address.
In addition to the standard background music, at the Music On Hold (MOH)
mode, UNICONT DTS-100 system allows to use other external music sources,
such as tape recorder or CD-player. XS5 (MUSIC) terminal block is used for
wiring of the external music source.

3.6. Power supply wiring

Main power supply is realized through XS6 terminal block. Backup power supply
(24V) is connected to the XS5 terminal block.
Please, check the polarity of power source cable.

3.7. Turning on the system

After system wall mounting, trunk and stations wiring and connecting, UNICONT
DTS-100 system is ready to be activated and programmed.
- Check the presence of the fuses.
- After supply mains connected, turn the power switch on, then the power
LED at the face panel inside will be lights on.

3.8. System programming

UNICONT DTS-100 System is shipped with presetting by default. The system
comes ready to use after the power is ON. Then you should program your
individual settings for system functioning in accordance to your requirements or
application. Use Digital Keyset supplied or PC to program the UNICONT DTS-
100 system.
The following sections are most commonly used basic settings with marine
adaptation. For more detailed information on system programming, please refer
to the manual "Programming Guide" given on CD supplied with the system.