Summary of Contents for Unicont DTS-100

  • Page 3: Table Of Contents

    User manual Rev 1.3 Contents 1. Introduction ........................4 2. System specifications....................5 2.1.. General overview ..................5 2.2. Maximum capacity ..................6 2.3. Electrical specifications ................6 2.4. Mechanical specifications ................6 2.5. Dimensions ......................6 2.6. Environment limitations ................6 2.7. Cable requirements ..................7 2.8. Power supply requirements ..............7 2.9.
  • Page 4: Introduction

    UNICONT DTS-100 1. Introduction All technical characteristics, specifications, commissioning procedure and maintenance of UNICONT DTS-100 key telephone system are given in the following manual. This information is intended for the technical specialists, performing mounting and testing of the system. Fig 1. System Connection Diagram...
  • Page 5: System Specifications

    It is basically a small communication system with big-company features usually not found from other similar PBXs. Outstanding feature in UNICONT DTS-100 is the ability to add digital feature into simple analog line without additional cost or a need of special equipment.
  • Page 6: Maximum Capacity

    Public address system ports External music source port * - 48 of internal stations is present, only in case of 1 digital and 47 analog or digital phones are connected to DTS-100. 2.3. Electrical specifications Input voltage 220-240 VAC , 50Hz...
  • Page 7: Cable Requirements

    User manual Rev 1.3 2.7. Cable requirements Equipment Cable Max distance Digital keysets 2 twisted pairs 24 (0,22 mm2) 400 m Single line station 1 twisted pair 24 (0,22 mm2) 1 km Add-on modules 1 twisted pair 24 (0,22 mm2) 400 m Door phone 2 twisted pairs...
  • Page 8: Phones

    UNICONT DTS-100 Fig 3. Physical configuration of key telephone of DTS-100 2.10. Phones The system is able to dial by means of either tone or pulse phones. It should be taken into consideration, that only tone dialing phones are suitable for programming the majority of functions.
  • Page 9 User manual Rev 1.3 Fig 4. Physical configuration and overall dimensions of Р-2350...
  • Page 10: Mounting And Wiring

    DTS-100 system. It is recommended to read this chapter thoroughly before mounting the system. 3.1. Site requirements When planning the installation of the UNICONT DTS-100 system, choose a site that meets the following requirements: - Select a location that minimizes cable lengths.
  • Page 11 User manual Rev 1.3 Fig 5. System overall and mounting dimensions...
  • Page 12: System Unpacking

    UNICONT DTS-100 3.2. System unpacking Check to see that the system package includes the following items (see also sec. 4): - system distribution cabinet; - mounting screws set; - digital keyset; - operating instructions; - technical manual. 3.3. Examination before mounting After unpacking the key telephone system, inspect for signs of physical damage inflicted during transit.
  • Page 13 User manual Rev 1.3 Fig 6. Labeling of the terminals...
  • Page 14: External Public Address System And External Music Source Wiring

    Public Address. In addition to the standard background music, at the Music On Hold (MOH) mode, UNICONT DTS-100 system allows to use other external music sources, such as tape recorder or CD-player. XS5 (MUSIC) terminal block is used for wiring of the external music source.
  • Page 15 User manual Rev 1.3 3.8.1. First time starting up Default settings (On the mainboard of system): - SW2 jumper – ON - Jumpers group SW1 – all in ON position, except 4. That configuration allows you to store all new settings. After switching on the power please wait until the system boots up.
  • Page 16 UNICONT DTS-100 3.8.4. P.A. relay contacts control - Enter the programming mode sec 3.8.2 - Enter 168, CO1 loop button - Press on 3 (choosing relay no. 1) - Press on HOLD/SAVE Verification: Pick up the phone, ring 545 and speak. At this moment, the system transmits the signal to P.A.
  • Page 17: Equipment Supplied

    User manual Rev 1.3 4. Equipment supplied - Marine telephone station UNICONT DTS-100 - System telephone - User manual - Original technical documentation and CD with all supported software and information.
  • Page 18: Transportation And Storage

    UNICONT DTS-100 5. Transportation and storage Transportation is performed using the cardboard wrapper at any enclosed transport facility. Marine telephone system UNICONT DTS-100 must be stored in enclosed space at –20…+45°C.
  • Page 19: Warranty

    User manual Rev 1.3 6. Warranty This product is warranted to be free of defects in materials and construction. Warranty period of storage life is within the 18 months from the date of initial purchase. Warranty period of service life is within the 12 months from the date of installation, but no longer than 18 months from the date of initial purchase.
  • Page 20: Purchase Information

    UNICONT DTS-100 7. Purchase information Marine telephone system UNICONT DTS-100 Serial number __________________ Firmware version _____________ Package date _____________ UNICONT Co. LTD Manufacturer Stamp here...
  • Page 21: Acceptance Report

    User manual Rev 1.3 8. Acceptance report Marine telephone system UNICONT DTS-100 is in accordance with documentation and is considered in working order. Serial number __________________ Delivered by: Company name _______________________________________________ Full name _________________________ signature _____________ Accepted by: Company name _______________________________________________...
  • Page 22: Installation Report

    UNICONT DTS-100 9. Installation report Marine telephone system UNICONT DTS-100 Serial number ___________________ The Unit has been commissioned. Date ___________________________ Place of installation: ___________________________________________________ ___________________________________________________ Installed by___________________________________________ (full name, signature) Serial number __________________ Delivered by: Company name _________________________________________________ Full name ______________________________...