Battery Removal/Installation - Hitachi WR 12DAF2 Handling Instructions Manual

Cordless impact driver/wrench
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
Attachment size
17mm
Type-L
12mm
Type-S
3. For WR12DAF2
The WR12DAF2 type is a 12.7 square driver
specification. Please select the socket with the
appropriate attachment size.
Optional accessories are subject to change without notice.
APPLICATION
〈WH12DAF2〉
Driving and removing of small screws, small bolts,
etc.
〈WR12DAF2〉
Tightening and loosening of all types of bolts and
nuts, used for securing structural items

BATTERY REMOVAL/INSTALLATION

1. Battery removal
Hold the handle tightly and push the battery latch to
remove the battery. (See Fig. 1 and 2)
CAUTION:
Never short-circuit the battery.
2. Battery installation
Insert the battery while observing its polarities. (See
Fig. 2)
Table 1
Blinks
Before
(RED)
charging
Lights
While
(RED)
charging
Blinks
Charging
(RED)
complete
Flickers
Charging
(RED)
impossible
Charging
Lights
impossible
(GREEN)
Purchase location
Republic of Korea,
13mm
Taiwan, Hong Kong,
People's Republic of
China, Republic of
Singapore
9mm
Other than above
regions.
Indications of the lamps
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Lights continuously
CHARGING
〈UC14YFA〉
Before using the power tool, charge the battery as follows.
1. Connect the charger's power cord to a receptacle.
When the power cord is connected, the charger's
pilot lamp will blink in red. (At 1-second intervals.)
2. Insert the battery into the charger.
Insert the battery firmly, in the direction shown in
Fig. 3, until it contacts the bottom of the charger
compartment.
CAUTION:
If the battery is inserted in the reverse direction, not
only recharging will become impossible, but it may
also cause problems in the charger such as deformed
recharging terminal.
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light up
continuously in red.
When the battery becomes fully recharged, the pilot
lamp will blink in red. (At 1-second intervals.) (See
Table 1)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or
the rechargeable battery.
English
Malfunction in the battery
or the charger.
The battery temperature
is
high,
making
recharging impossible.
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh 12daf2

Table of Contents