c. Power specification
(1).Output voltage
(2). Micro Controller control signal
Input signal(to PSU):
RLY signal ( High : Low Voltages*1are ON Low : Low Voltages are OFF)
VS ON signal (High : High Voltages*2are ON Low : High Voltages are OFF)
Output signal(from PSU)
ACD signal
(High : 75V < AC Input Voltage Low : 70V > AC Input Voltage)
5VD signal(High : Module logic Voltage*3is 5V Low : Module logic Voltage is 0V)
*1. Low Voltages : 5Vstand-by , 5Vsc, 9Vsc, 12Vsc, Vaudio
*2. High Voltages : Va, Vs
*3. Module logic Voltage : 5Vctrl