Dimensional drawings
392
50
171
150
189
224
50
Without cover
420
With cover
LK Systems AB, Box 66, 161 26 Bromma, Sweden | www.lksystems.se
Assembly instructions | LK Electric Boiler - 4,5
Technical data
Article no.
Height
Width
Depth
Weight
Output
Voltage
Current
Protection Class
Power circulation pump
Volume
Volume expansion vessel
Calculation pressure
Test pressure
Safety valve
Calculation temperature
Control temperature
Manufactured in accor-
dance with:
Fuse
Condensing boiler
Low-temperature
B1 boiler
Cogeneration space heater
Combination heater
Rated heat output
Useful heat output at rated
heat output
Energy class
Seasonal space heating
energy efficiency
Useful efficiency
Auxiliary electricity
consumption
Standby heat loss
Material recycling
After dismantling the boiler must be recycled.
The insulation is removed and recycled as insula-
tion. Boiler Body recycled as scrap steel. Electrical
and electronic components are sorted as electro-
nic waste. Boiler casing recycled as plastic.
623 12 25
700 mm
420 mm
200 mm
17 kg
4,5 kW
400V AC 3N~, 50 Hz
6,5 A
IP 21
2-34 W
5,5 litres
2 litres
2,5 bar
3,6 bar
2,5 bar
80 °C
10-60°C
AFS 1999:4§8 97/23 EG
article 3
3 x 10A
no
no
no
no
no
P
5
kW
rated
P
4,5
kW
4
D
boiler
η
36
%
s
boiler
with
η
38
%
s
UTK
η
39,7
%
4
in stand-
P
0,019
kW
SB
by mode
P
0,037
kW
stby
EN.33.C.111.1804
9 (9)