SPECIAL AGING MODE FUNCTIONS
The aging mode is provided with the following convenient func-
tions
• Disc setting mode (*1)
• Selection of presence of protection function during error (*2)
• Count function of aging cycle (*3)
*1 Disc setting mode:
5 discs are set before setting the aging mode. This mode makes
the setting of these discs more easy.
*2 Self protection function during errors:
Function which voluntarily corrects errors which occur during
normal operations by retries.
If this function is not provided, all operations will be stopped
without retiring. It is suitable for checking errors with low
reproducibility.
If this function is provided, and errors can be corrected by
retries, aging will be continued without stopping.
*3 Aging cycle count function:
Functions which displays the number of agings carried out on
the Fluorescent indicator tube in numbers. One aging cycle
consists of five discs.
Error code
Code number
#Err 01
DISC sensor check 1
#Err 02
DISC sensor check 2
#Err 03
Table operation check 1
#Err 04
Table operation check 2
#Err 05
Loading operation check 1
#Err 06
Loading operation check 2
#Err 08
Table stop precision check 1
#Err 09
Table stop precision check 2
#Err *1
BU related check 1
#Err *2
BU related check 2
#Err *3
BU related check 3
#Err *4
BU related check 4
#Err *5
BU related check 5
#Err *6
BU related check 6
The * numbers mean the following according to the state of the unit during aging
2 : From chucking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback
# : DISC No.
Name
No disc in the specified slit
Disc in other slits
Table motor current over
No table sensor input
Load in timeover
Load out timeover
Table is not stopped within the specified time.
Stopped while both T.SENS 1 and 2 are "LOW".
Access timeover
During high speed playback, COUNT timeout
Q data read error
]BU operation (from focus search to until signal can be read) timeover
GFS monitor error
Focus cannot be imposed by focus search
AGING PROCEDURE
1.
Turn on the power and press the GROUP FILE , MEGA CTRL
and I/
1
buttons.
2.
Rotate DISC/CHARACTER knob, select "Normal Aging"
and press the button to start the aging mode.
3.
When the disc set mode is set, the
4.
Rotate the DISC/CHARACTER knob. The slits (No. 80, 160,
400, 240, 320) for setting the discs will come forward. Insert
the discs into these slits. Do not set the discs in other slits.
5.
Set whether the self-protection function during errors is
equipped with the unit. Press the REPEAT button. If
"REPEAT" is displayed on the fluorescent indicator tube, it
means the function is provided. If "REPEAT" is not displayed,
it means the function is not provided.
6.
Press the
H
button.
7.
The
LED blinks, the aging mode is set, and aging is started.
H
8.
The aging cycle lasts 3 minutes. If errors occur during aging,
the error number will be displayed on the fluorescent indicator
tube. (Refer to the following table for the details of the errors.)
9. Aging will be repeated as long as no errors occur.
10. After each aging cycle, the number displayed on the Fluorescent
indicator tube will increase.
11. To end aging, to end aging, press the I/
standby mode.
Contents
H
and
X
LEDs blink.
button to enter the
1
13