Installation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual
The purpose of this manual is to aid in the proper installation and operation of fans
manufactured by S&P USA. These instructions are intended to supplement good
6393 Powers Ave
Jacksonville, FL 32217
P: 800.961.7370
F: 800.961.7379
The purpose of this manual is to aid in the proper installation and operation of fans
manufactured by S&P. These instructions are intended to supplement good general
practices and are not intended to cover detailed instruction procedures, because of
the wide variety and types of fans manufactured by S&P.
The purpose of this manual is to aid in the proper installation and operation of fans
manufactured by S&P USA. These instructions are intended to supplement good
general practices and are not intended to cover detailed instruction procedures,
because of the wide variety and types of fans manufactured by S&P USA.
6393 Powers Ave
Jacksonville, FL 32217
P: 800.961.7370
F: 800.961.7379
MD6-ES24VK-IOM_v.1 / 06-2018
MD6-ES24VK
READ AND SAVE THESE INSTRUCTIONS
general practices and are not intended to cover detailed instruction procedures,
because of the wide variety and types of fans manufactured by S&P USA.
READ AND SAVE THESE INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MD6-ES24VK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for S&P MD6-ES24VK

  • Page 1 S&P USA. These instructions are intended to supplement good general practices and are not intended to cover detailed instruction procedures, because of the wide variety and types of fans manufactured by S&P USA. 6393 Powers Ave Jacksonville, FL 32217 P: 800.961.7370 F: 800.961.7379 MD6-ES24VK-IOM_v.1 / 06-2018...
  • Page 3: Installation Instructions

    6. Ducted fans must always be vented to the outdoors. PRE-INSTALLATION INSPECTION The MD6-ES24VK has been manufactured in accordance with rigorous standards of production. All the components have been checked and tested at the end of the manufacturing process. We recommend that you check the following after receiving this product: 1.
  • Page 4 MOUNTING Choose a mounting location which allows convenient wiring and maintenance accessibility. The MD6-ES24VK can be mounted in any orientation, horizontal or vertical, and is suitable for supply/fresh air applications. The 6” MD6 motorized damper will be installed between the fresh air wall cap/roof cap/soffit vent (with insect screen) and the HVAC unit return duct.
  • Page 5 CAUTION: Ensure that power is turned off and locked out before making any wiring connections. The MD6-ES24VK operates from a standard 24V 60Hz AC electrical supply. There are multiple wiring scenarios available depending on the installer preferences. The diagrams below show 3...
  • Page 6 TS TS SENSOR SENSOR SENSOR SENSOR COMMON TRANSFORMER ES24V - (20VA NOT AVAILABLE FOR DIRECT CONNECTION ES24V - (20VA REQUIRED TO OPERATE MD6 MOTORIZED DAMPER. CLASS II POWER SUPPLY CAN COME FROM HVAC TRANSFORMER, OF MOTORIZED DAMPER) IF ADEQUATE, OR AUXILIARY TRANSFORMER IF NECESSARY) FIGURE 1 FIGURE 2 SENSOR...
  • Page 7: Airflow Setting

    AIRFLOW SETTING CAUTION: Refer to local and national Ventilation and Indoor Air Quality standards to ensure the proper airflow rate. Ensure the HVAC unit air filter is clean and installed. Turn the ES24V to the “ON” position and wait approximately 10 seconds for the HVAC unit fan to turn on and the MD6 motorized damper to open.
  • Page 8: Maintenance

    Airflow / Air Velocity Reference Table Duct Size (in) Airflow (CFM) Air Velocity (FPM) 1019 Note, if the Actual Measured CFM is not enough, the installer may need to increase the duct size or add a booster fan if necessary. Ensure there is no blockage in the ductwork first. MAINTENANCE CAUTION: BEFORE CARRYING OUT ANY MAINTENANCE OR SERVICING, ENSURE THE UNIT IS DISCONNECTED FROM THE MAIN ELECTRICAL SUPPLY.
  • Page 9: Warranty

    WARRANTY S&P USA - S&P Canada warrant that the MD6-ES24VK will be free from defective materials and workmanship for the period of (5) years from the date of original purchase. In the event that we find any part is defective the product will be repaired or, in the Company’s...

Table of Contents