Baileigh IP-2008-HD Operator's Manual page 49

Table of Contents

Advertisement

Trouble
Machine will not
start/restart or
repeatedly trips circuit
breaker or blows
fuses.
Planer does not come
up to speed.
Probable Cause
Motor starter failure.
Motor failure.
Miswiring of the machine.
Switch failure.
Low current.
Remedy
Examine motor starter for burned or
failed components. If damage is
found, replace motor starter. If motor
starter looks okay but is still suspect,
you have two options: have a qualified
electrician test the motor starter for
function, or purchase a new starter
and establish if that was the problem
on change out.
If you have access to a voltmeter, you
can separate a starter failure from a
motor failure by first, verifying
incoming voltage at 220+/-20 and
second, checking the voltage between
starter and motor at 220+/-20.
If incoming voltage is incorrect, you
have a power supply problem.
If voltage between starter and motor is
incorrect, you have a starter problem.
If voltage between starter and motor is
correct, you have a motor problem.
If electric motor is suspect, you have
two options: Have a qualified
electrician test the motor for function
or remove the motor and take it to a
quality electrical motor repair shop
and have it tested.
Double check to confirm all electrical
connections are correct. Refer to
wiring diagram to make any needed
corrections.
If a start, stop, or table movement
switch is suspect, you have two
options: Have a qualified electrical
test the switch for function, or
purchase a new switch and establish
it that was the problem on change out.
Contact a qualified electrician.
46