Chapter 3 Management through the Web
T1/E1 Triggers
TCLE
Optical Triggers
LOS
RXBER
RDI
Optical A LOS
Optical B LOS
Loopback Triggers:
All Remote and Local (Ethernet, Optical, and T1/E1)
Physical Status Triggers:
Loss of Power (Power A or Power B)
Unit Temperature > 90 C
3-6
Transmit Current-Limit Exceeded. TCLE indicates
that there is a short on the T1/E1 channel's transmit
pair. Common sources of this problem is damaged
cables or a faulty receiver at the far end.
Loss of Signal (Optical)
Receive Bit Error Rate Threshold Exceeded
Remote Defect Indication
Optical A Port LOS
Optical B Port LOS