Safety instructions
Description of functions
The temperature controller controls the room
The unit may only be opened by an electrician
or floor temperature according to the set target
and installed according to the circuit
temperature and is equipped with an internal sensor
diagram on the unit or in these instructions.
Observe existing safety instructions.
for measuring the room temperature. In addition,
an external remote sensor can be connected,
To satisfy the requirements of protection class II,
for example to measure the floor temperature.
corresponding installation measures are required.
The temperature controller compares the measured
This independently-mountable electronic device
temperature with set values. If the temperature falls
is exclusively for controlling the temperature in
below the current setting, the heating system is
dry, enclosed rooms with normal surroundings.
turned on.
This device conforms with EN 60730 and
Two temperature values, T+ and T-, can be preset
functions according to operating mode 1C.
Damage to the device, fire or other hazards may
(comfort and reduction temperature), between which
it is possible to switch at the touch of a button.
arise if these instructions are not followed.
Optionally, an external switch (e.g. a timer) can
These instructions are a component part of the
be used to control the temperature automatically
product and must remain with the end customer.
to another preset ECO value.
Structure of the device
The control method depends on the type of heating
and is determined by the installer:
– Room temperature controller: The heating
(1)
is turned on when the room temperature
(2)
falls below the set target temperature
(3)
(measured with an internal sensor or external
remote sensor).
(4)
– Floor temperature controller: The underfloor
heating is turned on when the floor temperature
falls below the set target temperature
(measured using an external remote sensor).
(5)
– Room temperature controller with a limiter:
(in conjunction with underfloor heating):
The room temperature is measured
(6)
and regulated using the internal sensor.
An additional external remote sensor is
(7)
connected to measure the floor temperature,
and a target temperature range for the floor
is set. The room temperature control is
deactivated when the floor temperature is
outside of this range. If temperature falls below
Fig. 1: Layout of the temperature controller
this range, the heater is turned on, and if the
(1) Controls
temperature is above this range, the heater
(2) Display
is turned off independent of the current room
temperature.
(3) Control buttons
(4) Plug-in contacts
Operation
(5) Design frame (not including delivery)
(6) Socket for the plug-in contacts
(7) Use
Function
Correct use
– Measuring and controlling the room temperature
(9)
– Measuring and controlling the floor temperature
– Room temperature control via floor heating with
a limiting function (for example in conjunction
with tiled stoves)
(8)
– Can be used for "heating only" or "cooling only"
– Installable in a box in conformance with
DIN 49073
– Only for use in dry, enclosed rooms
Product characteristics
– Large display with backlighting
– Text display for self-explanatory operation
(16)
– Different user languages can be selected
– Internal temperature sensor
Fig. 2: Default display
– An external remote sensor can be connected
– ECO input [clock] for the activation of a freely-
(8) Function display (such as the mode)
settable temperature, e.g. for night reduction
(9) Large display (such as the current temperature)
– Time limit for the manually-selected temperature
(10) –
– Simply switch between 2 temperatures (comfort,
(11) Heating mode display
reduction)
(12) Display (e.g. target temperature)
– Short-time timer ("party function")
(13)
O
button (OK, switchover T+/T−/ECO)
– Frost protection function
(14)
button
+
– Display of energy consumption for electric
(15)
-
button
heating systems
(16)
M
button (menu)
– Pulse width modulation (PWM) or two-point
control system
– Adjustable cycle time (PWM), hysteresis and
minimum on/off time (two-point)
– Switch on delay, such as for burners (with two-
point control)
– Adaptation to valves normally open or closed
– Valve protection (as a room temperature
controller with and without a limiting function)
– Resetting separate from user and installer
settings
Basic information
Four buttons below the display are used to operate
the temperature controller (Fig. 2, items (13) to (16)).
In the menu, you can activate operating modes
and make settings. If a button is not pressed for
more than three minutes, the unit automatically
switches back to the previous function and the basic
display (Fig. 2).
Operation when the controls are removed
The unit can also be operated when the controls are
removed. The current temperature is not displayed,
the "heating mode" display flashes, and the display
is not illuminated. If a button is not pressed for more
than three minutes, the display goes dark.
Display information on the current mode
To go to the default display when the controls
W
W
are removed and the display is dark, press any
button.
■ Press
in the default display.
O
Information on the current mode/setting is
displayed.
■ Return to the default display by pressing
Selecting modes and setting menus
■ Press
in the default display.
M
MENU briefly appears in the function display (8).
A help text as a marquee appears at the bottom
edge of the display.
■ Use the
/
buttons to switch to the desired
+
-
mode/setting.
■ Select the desired mode/setting by pressing
Another menu opens depending on the
mode/setting.
■ Go back to the last display/setting by
pressing
.
M
■ Return to the default display by pressing
several times.
Manually adapting the target temperature
You can always adapt the target temperature in
modes CONTROL and TIMER.
or
■ In the default display, press
+W
W-
The current target temperature flashes.
■ Set the desired temperature by pressing
■ Accept the displayed temperature by pressing
The device returns to the default display.
Turning off the control
(11)
■ In the default display, press the
button for
M
10 seconds.
(12)
First "MENU" appears in the display.
After 10 seconds, the device switches to the
default display and "OFF" appears.
■ Turn the controls back on by selecting a mode.
(15)
(14)
(13)
Main menu
User settings
Modes and setting menus (overview 1)
Overview 2
To follow is an overview of the modes and setting
A marquee at the bottom of the display shows
menus within the main menu.
information for an individual menu items identified
with G1 to G16.
CONTROL
W
W
The menu item G3 is not available and,
Control of the temperature to the value set here:
depending on the set control procedure,
T+ = Comfort temperature
the menu items G11 and G12 are not available.
T− = Reduction temperature
ECO = When the ECO function is active, the preset
(The menu displays and set all values are in
temperature or that set here.
UPPERCASE, and the settings are bold)
T* = Temperature changed with
/
+
-
G1 T+ TEMP
TIMER
Presetting of the comfort temperature:
Short-time timer to specify the room temperature
– For H1 = ROOM or LIMITER:
for a set number of hours ("Party function").
OFF, 5.0 °C, 5.5 °C ... 21.0 °C ... 30.0 °C
■ Press
+
/
-
to set the hours and confirm
– For H1 = FLOOR:
with
.
OFF, 10.0 °C, 10.5 °C ... 28.0 °C ... 40.0 °C
O
Press
■ Press
/
to set the temperature and
+
-
with
O
confirm with
O
.
G2 T− TEMP
The display (12) shows the number of
Presetting of the reduction temperature:
remaining hours.
– For H1 = ROOM or LIMITER:
On exiting, that mode is continued which was
OFF, 5.0 °C, 5.5 °C ... 18.0 °C ... 30.0 °C
active before TIMER. TIMER continues when
O
.
– For H1 = FLOOR:
ECO is activated and ECO is delayed accordingly.
OFF, 10.0 °C, 10.5 °C ... 18.0 °C ... 40.0 °C
Manual exiting of TIMER by selecting the
Press
CONTROL mode.
with
O
USER SETTINGS
G4 OFF HEATING PERMANENT
Open the menu for the user settings.
Turn off the temperature control:
The display (9) shows the menu ID G1.
– YES = Control off
■ To select the desired submenu, see "User
– NO = Control on
settings".
Select YES/NO with
If OFF HEATING PERMANENT = YES is selected,
.
O
the frost protection is active, provided that it has
Open the setting menu for the installer.
been set by the installer, see also Installer settings
The display (8) shows the menu ID H1.
H6 - FROST PROTECTION ≠ OFF.
■ To select the desired submenu, see "Installer
Display function (8): OFF
settings".
Turn on the control again: Select a function using
the menu, or hold
Overview 1: Modes and setting menus
M
G5 T* MAX LENGTH
Select the desired mode/setting menu
The maximum validity period for T* can be set,
The device is in the default display.
e.g. setting to 3 hrs: After 3 hrs, the previously
button.
■ Press the
selected temperature (T+, T−, ECO) is used.
MW
– OFF, 1 hrs, 2 hrs ... 23 hrs
The help text "MENU..." appears at the bottom
Select the number of hours with
edge of the display.
.
confirm with
■ Press the buttons
+
/
-
until the desired menu
G6 KEY LOCK
item (mode or setting menu) appears.
/
.
Protect the controller against unauthorized use.
+
-
■ Confirm with
O
.
Use is not possible when access protection is
O
.
enabled.
The function is activated in modes CONTROL
– YES = access protection on
and TIMER.
– NO = no access protection
With the other menu items, the device jumps to
Select YES/NO with
additional settings (see overview 1).
Remove access protection: Press any button,
and when CODE is displayed, set 93 with
and confirm with
G7 TEMP LIMIT MIN/MAX TEMP
Set the lower and upper temperature to be
controlled:
– LOWER TEMP LIMIT:
For room temperature controller
(H1 = ROOM or LIMITER):
5.0 °C, 5.5 °C ... 30.0 °C
For floor thermostat (H1 = FLOOR):
10.0 °C, 10.5 °C ... 40.0 °C
– UPPER TEMP LIMIT:
For room temperature controller
(H1 = ROOM or LIMITER):
5.0 °C, 5.5 °C ... 30.0 °C
For floor thermostat (H1 = FLOOR):
10.0 °C, 10.5 °C ... 40.0 °C
Set the temperatures with
In CONTROL mode, the temperature range is
limited to the values set here.
G8 COSTS/HR OF ENERGY
Enter the estimated energy costs per hour for the
room in which the temperature is being controlled:
1, 2, ... 100 ... 999 CENT/HR
If the energy cost meter is to serve
W
W
as an operating hour meter, set the value
COST/HR to 100.
Set COST/HR with
The determined consumption is displayed
under G9.
G9 ENERGY CONSUMPTION TO DATE
Display of the approximate energy consumption
in euros (or operating hours) per time period.
The current day is included up to the displayed time.
Calculation: Time heat turned on x COST/HR (G8).
EURO/2DAYS, EURO/WEEK, EURO/30DAYS,
EURO/YEAR.
Select the period for calculating the energy
consumption, display it with
menu with
O
.
Reset using INSTALLER SETTINGS (H9)
G10 DISPLAY TARGET TEMP
Setting for the target temperature to be shown in
the display instead of the current room temperature:
– YES = Target temperature
– NO = Room temperature
Select YES/NO with
+
/
-
G11 ADJUST TEMP
+
/
-
to set the temperature and confirm
.
This menu item is not available when used as
W
W
a floor temperature controller.
Specify a correction value to be displayed and
regulated:
-5.0 °C, -4.9 °C ... 0.0 °C ... 4.9 °C, 5.0 °C
Useful adaptations are for example matching
W
W
calibrated thermometers, or adapting to
/
to set the temperature and confirm
+
-
installation heights or locations that are
.
problematic.
Adjust the correction value with
with
.
O
G12 NUMBER FOR FLOOR TEMP
W
W
This menu item is not available when used
+
/
-
, confirm with
O
.
as a room temperature controller with/without
a limiting function.
Activate the floor temperature display for
information (without the unit °C).
– YES = display the floor temperature
– NO = display the room temperature
M
for 10 s.
Select YES/NO with
/
+
-
G13 BACKLIGHT
Set the display lighting:
– SHORT = short time after pressing the button
– OFF = always off
– PERMANENT (only when using a remote sensor)
/
,
+
-
Select SHORT/OFF or PERMANENT with
.
O
confirm with
.
O
G14 LANGUAGE
Select the language for the texts shown in the
display: GERMAN, ENGLISH, DUTCH, FRENCH,
RUSSIAN, SPANISH, ITALIAN, POLISH, TURKISH
Select the LANGUAGE with
with
.
O
/
, confirm with
.
+
-
O
G15 INFO
Display controller type and controller version:
+
/
-
TR D ...
.
O
Display the controller version with
to menu with
M
or
O
.
G16 RESET USER SETTINGS ONLY
Reset the user settings to the defaults.
The counter ENERGY CONSUMTION TO
W
W
DATE is not reset. This is reset by the installer
in the menu H9.
– YES = reset
– NO
Select YES/NO with
/
+
-
Overview 2: User settings
+
/
-
and confirm with
O
.
/
, confirm with
.
+
-
O
Temperature management
Standard room temperature controller with display
+
/
-
, go back to the
Art. No.: TR D .. 231 ..
Operating and installation instructions
, confirm with
O
.
EN
ALBRECHT JUNG GMBH & CO. KG
Volmestrasse 1
58579 Schalksmühle, Germany
Telephone: +49 (0)2355 8060
+
/
-
and confirm
Fax: +49 (0)2355 806204
kundencenter@jung.de
www.jung.de
Service Centre
Kupferstr. 17-19
44532 Lünen
Germany
, confirm with
.
O
27.05.2014
0024073400
Open the settings menu and make settings
The display shows the menu code G1 in the display
/
,
+
-
(9) and, beneath that, the marquee T+ SET.
■ Press
+
/
-
to select the desired menu.
The menu ID and a help text appear at the
bottom edge of the display (8) and (12).
■ Confirm with
.
O
+
/
-
, confirm
The first settable value flashes in the display.
■ Set the desired value by pressing
+
/
-
.
■ Confirm with
.
O
The next settable value flashes in the display.
,
+
/
-
go back
Once all the values are set, the display returns
to the higher level and displays the menu ID.
, confirm with
.
O