Use the following steps to install the 505–6870 RBC in a Series 505 base or
to install the 500–6870 RBC in a Series 500 base.
Installing or removing an RBC from a powered-up base disrupts your process
and can damage the RBC. Disruption of your process can cause death or
serious injury to personnel, and/or damage to equipment.
Ensure that all power is disabled before installing or removing the RBC.
The RBC is sensitive to, and can be damaged by, electrostatic discharge.
Ensure that personnel make contact with a static-dissipative pad and/or wear a
grounded wrist strap when handling the RBC.
1.
Verify that all jumper settings on the 505 RBC or the Off/Freeze toggle
switch on the 500 RBC are correct. See Section 4. It is advisable to set
the dipswitch options before installing the module. See Section 5.
2.
Disconnect power to the base.
3.
Position the RBC so that the bezel is facing you.
4.
Grasp the top and bottom of the RBC.
5.
Carefully push the RBC into the slot until it mates with the backplane
connector.
6.
Tighten the top and bottom bezel screws.
Series 505 RBCs are not designed to be installed in VME bases. Doing so
results in damage to equipment.
Never attempt to install any Series 505 RBC in a VME base.
To remove the RBC, complete the following steps.
1.
If attached, remove cables from the RBC.
2.
Disconnect power to the base.
3.
Loosen the top and bottom bezel screws.
4.
Carefully pull the RBC from the base.