SmartPath
INSTALLATION INSTRUCTIONS
ELT03100
DESCRIPTION
The IRE-1.0 represents the highest level in sophistication for attachable
IR Emitters. It features a unique EZ-Docker
removal of the emitter when rearranging or servicing components.
An improved adhesive reduces callbacks for reattachment of "fallen
emitters". The case may also be taken apart so that the tiny internal
emitter can be placed inside a component, when desired. High IR
output from the top curved surface allows emitter to be mounted on
a nearby surface, below, above or on a cabinet door, rather than
directly on the sensor of the unit where conditions
permit.
(+)
Fig. 1
ATTACHMENT
First, locate the component' s IR sensor window (see Note 1) and
thoroughly clean it of any fingerprints or other greasy substances.
The EZ-Docker
Peel the protective layer off,
exposing the adhesive.
Orient the port vertical (see
Fig. 2) and press it over the
center of the component' s
sensor window. Press and
hold for several seconds to
ensure maximum contact
of the adhesive.
Slide the emitter from the
top down, into the EZ-
Docker
™
port. You should
feel it "snap" into place. (To
remove the emitter at any
time, simply push upward
until it "pops" out).
Insert the 3.5mm plug into an Emitter jack on a SpeakerCraft
Terminator or other source of IR (see Fig. 3).
CAUTION: Do not plug into an emitter jack that is set to Blaster
Power (BL ON) or to the HIGH OUT of other connecting blocks.
To do so will smoke the emitters!!
Note 1: If you have difficulty finding the component' s IR sensor, try
using a flashlight. Sometimes the owner' s manual is helpful. You may
need to contact the manufacturer direct.
Note 2: You may also attach the emitter without the EZ-Docker
Use one of the spare adhesives (included) applying it directly to the
bottom surface of the IRE-1.0 shell.
Note 3: If you need to remove the EZ-Docker
ously stuck to a component' s surface, use a fresh adhesive (included)
before reattaching.
Note 4: The emitter shell and EZ-Docker
appearance, are transparent to Infrared. This allows IR commands to
pass through them, permitting local hand held remote control as
well as through the IRE-1.0.
3.5mm
mini plug
(– )
Clear Adhesive Tape
(See Note 3)
™
port has a clear adhesive layer on its bottom surface.
IRE-1.0
IR Emitter
™
IRE-1.0
Emitter
Top View
NOTE: White striped side is positive ( +)
8 FT
Side View
Wire Lead
Docking
Port
IR Controlled Components
1) Attach IRE-1.0 Docking Port
to IR sensor window with adhesive pad
IRE-1.0 attached to
IR sensor window
™
™
port that permits instant
9/16"
Emitter
Emitter slides into
Docking Port
1/4"
™
port or emitter previ-
port, though dark in
LIT03100 02/02
7/16"
Fig. 2
2) Slide IRE-1.0 Emitter
end into docking port
Docking Port
IR sensor
window
™
port.
Need help?
Do you have a question about the SmartPath IRE-1.0 and is the answer not in the manual?
Questions and answers