LONG TERM STORAGE

These instructions must be followed in order to obtain warranty coverage for long term storage
engines. These procedures are intended to prevent oxidation and deterioration of engine and
fuel system components.
Engines stored for more than one (1) year must be inspected properly to ensure that they are
in good condition.
• Engines used within one (1) year from factory release.
- No specific action is required.
• Engines stocked more than one (1) year from factory release( To check every 6 months )
1) Carefully inspect & check all parts for damage and/or corrosion.
2) The coolant must be replaced for long term storage. Use 50% Glycol containing anti-
corrosion additives and 50% distilled water.
3) Check all anodes and replace if required.
4) Storage conditions should be between 15~30⁰C and less than 50% relative humidity.
• Engines for use after long term storage and/or long term inactivity.
1) Carefully inspect and check all parts for damage and/or corrosion.
2) The coolant and lubricants must be replaced before using the engine.
3) The oil filter and fuel filter must be replaced before using the engine.
4) The seawater pump impeller must be replaced before using the engine.
5) The thermostat and anodes must be checked and replaced if necessary
6) Crank the engine without starting to lubricate the inside of the engine. Please
disconnect the Crank Position Sensor to prevent engine start while lubricating the engine.
7) Run the engine 10 minutes at idle RPM with no load before putting into service.
8) Refer to Pre-Delivery checklist to inspect entire engine condition and installation.