Sets the length of time the modem will stay online before disconnecting when no data is sent or
received. In Reliable mode, any data transfer resets timer. In Normal mode, only sent data
resets timer.
XOn Character
(range = Ø-255; default = 17)
XOff Character
(range = Ø-255; default = 19)
S36 Negotiation Failure Treatment
(range = Ø-7; default = 7)
Fallback options initiated when S48=128 or an attempted error correction link fails.)
Value
Treatment
(Dec)
Ø
Disconnect.
1
Establish a Direct connection.
2
Undefined.
3
Establish a Normal connection.
4
Establish an MNP connection if possible. Otherwise, disconnect.
5
Establish an MNP connection if possible. Otherwise, establish a Direct
connection.
6
Undefined.
7
Establish an MNP connection if possible. Otherwise, establish a
Normal connection.
Bits 3 - 7 reserved.
S37 Desired DCE Speed
S38 Delay Before Forced Disconnect
(range = Ø-255; default = 5; units = seconds)
The delay between your modem receiving the H command (or an on-to-off transition of DTR if
your modem is set to follow DTR) and disconnecting. If S38 is between Ø and 254, your
modem waits for the seconds from H command for the remote modem to acknowledge all data
in the modem buffer before disconnecting. NO CARRIER indicates time expired before all data
was sent, and data has been lost. OK indicates all data was transmitted. If S38 is 255, the
modem attempts to deliver data in the buffer until the connection is lost or the data is
delivered.
S40 Inactivity Timer
Value: Ø-255 minutes; Ø = Inactivity timer disabled; default = Ø
Type : Storable
77