  • Page 1 User’s Manual Wide Range Mini InfraRed Thermometer with Laser Pointer MODEL 42510A GlobalScientificSupply GLOBAL SCIENTIFIC SUPPLY info@GlobalScientificSupply.com www. .com The Laboratory Supply Company!
  • Page 2 Introduction Congratulations on your purchase of the Model 42510A IR Thermometer. This Infrared thermometer measures and displays non-contact temperature readings up to 650 C (1200 F). The adjustable emissivity feature allows the IR thermometer to measure the temperature of virtually any surface.
  • Page 3: Function Buttons

    C or F temperature units Main temperature display Low battery icon 10. MAX or MIN icon 11. Emissivity setting 12. Emissivity icon 13. MAX or MIN temperature display 42510A-EU-EN-V3.4 4/13 GlobalScientificSupply GLOBAL SCIENTIFIC SUPPLY info@GlobalScientificSupply.com www. .com The Laboratory Supply Company!
  • Page 4: Operating Instructions

    5. Note: The backlight will shorten the battery life; use sparingly and only as necessary. Over-range Indication If the temperature measurement exceeds the specified temperature range, the thermometer will display dashes in place of a temperature reading. 42510A-EU-EN-V3.4 4/13 GlobalScientificSupply GLOBAL SCIENTIFIC SUPPLY info@GlobalScientificSupply.com www.
  • Page 5: Emissivity Adjustment

    LCD display icon. The alarm limit is set and the feature is enabled/disabled in the programming mode. The setting is stored and memory and will remain as the ON condition until changed. 42510A-EU-EN-V3.4 4/13 GlobalScientificSupply GLOBAL SCIENTIFIC SUPPLY info@GlobalScientificSupply.com...
  • Page 6 In addition, the spot size may be so large that it encompasses surface areas not intended to be measured. 4” 2” @48” 1” @24” @12” 2.54cm 10cm @30.5cm @61cm @122cm 42510A-EU-EN-V3.4 4/13 GlobalScientificSupply GLOBAL SCIENTIFIC SUPPLY info@GlobalScientificSupply.com www. .com The Laboratory Supply Company!
  • Page 7 Emissivity values range from 0.1 for a very reflective object to 1.00 for a flat black finish. For the Model 42510A, the emissivity is adjustable from 0.1 to 1.00. Most organic materials and painted or oxidized surfaces have an emissivity factor of 0.95. When in doubt, set the emissivity to 0.95.
  • Page 8: Specifications

    82 x 42 x 160mm (3.2 x 1.6 x 6.3”) Copyright © 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO-9001 Certified 42510A-EU-EN-V3.4 4/13 GlobalScientificSupply GLOBAL SCIENTIFIC SUPPLY info@GlobalScientificSupply.com www.