  • Page 1 Eclipse 5 with autoSAT ® ® User Manual (English)
  • Page 2 Eclipse 5 User Controls & System Status Indicators Internal Symbols This way up. Reg. # 0623 External Power Indicator Fragile, handle with care. Reg. # Power Cartridge (battery) Status 0621 Gauge Keep away from rain, keep dry. Reg. Power Cartridge Symbol...
  • Page 3 The air we breathe contains approximately 21% WEEE oxygen, 78% nitrogen, and 1% other gasses. In the Eclipse 5, room air is drawn into the machine IEC 60601-1: Medical electrical equipment Part through the air intakes. It then passes through an 1 General requirements for basic safety and adsorbent material called molecular sieve.
  • Page 4 2 Getting to Know Your Eclipse 5 Review all Warnings, Cautions and additional de- vice information in the rest of this manual. Become Eclipse 5 familiar with the key features of the Eclipse 5 and the User Control Panel. FRONT Handle...
  • Page 5 Delivery Mode Button and Indicator: The button toggles between Contin- uous Flow and Pulse Dose Mode. The When the Eclipse 5 is plugged in properly, a green Pulse Dose Mode activates autoSAT indicator on the AC Power Supply will light and...
  • Page 6 Universal Cart. Align the large Continuous Flow Mode Display threaded screw to the insert at the back of the Eclipse 5. Then hand-tighten the knob on the cart until the Universal Cart is tightly secured to the device. Depress the push-button on the telescoping Universal Cart handle to adjust the height of the handle.
  • Page 7: Safety Guidelines

    PERIODS OF NON-OPERATION AS A RESULT OF ELECTRICAL POWER INTERRUPTION, OR THE WARNING: IT IS VERY IMPORTANT NEED TO HAVE THE ECLIPSE 5 SERVICED BY A TO SELECT ONLY THE PRESCRIBED QUALIFIED TECHNICIAN. THE ECLIPSE 5 IS NOT LEVEL OF OXYGEN. DO NOT CHANGE...
  • Page 8 Eclipse 5 WARNING: THE CONCENTRATOR WARNING: IF YOU FEEL DISCOMFORT OR ARE SHOULD BE LOCATED AS TO AVOID EXPERIENCING A MEDICAL EMERGENCY, SEEK SMOKE, POLLUTANTS OR FUMES. MEDICAL ASSISTANCE IMMEDIATELY. WARNING: THE USE OF SOME OXYGEN ADMIN- WARNING: OPERATING THE OXYGEN CON-...
  • Page 9 Eclipse 5 WARNING: THE CONCENTRATOR WARNING: THE US DEPARTMENT OF TRANS- SHOULD BE LOCATED AS TO AVOID PORTATION (DOT) AND UNITED NATIONS (UN) SMOKE, POLLUTANTS OR FUMES. REGULATIONS REQUIRE THE REMOVAL OF THE BATTERY FROM THE DEVICE FOR ALL INTERNA-...
  • Page 10 Eclipse 5 WARNING: ONLY ACCESSORIES RECOMMENDED WARNING: “NO SMOKING – OXYGEN IN USE” BY THE MANUFACTURER. USE OF ANY OTHER SIGNS MUST BE PROMINENTLY DISPLAYED MAY BE HAZARDOUS, CAUSE SERIOUS DAMAGE IN THE HOME, OR WHERE OXYGEN IS IN USE.
  • Page 11 Eclipse 5 CAUTION: Always place oxygen supply tubing CAUTION: In the event of an alarm or and power cords in a manner that prevents a you observe the Oxygen Concentrator trip hazard. is not working properly; consult the Troubleshooting section in this manu- CAUTION: When using the Oxygen Concen- al.
  • Page 12: Specifications

    Must be smoke, pollutant, and fume free. Available Settings Operating Time 24-hours a day when connected The Eclipse 5, including the cannula and other to an external AC or DC power accessories, are specified for use at the following source.
  • Page 13: Operating Instructions

    Users Manual. In order to reduce OXYGEN CONCENTRATOR IN THE the risk of fire, personal injury and serious damage PRESENCE OF FLAMMABLE GASES. to the Eclipse 5, please observe all of the safety THIS CAN RESULT IN RAPID BURNING precautions. CAUSING PROPERTY DAMAGE, BODILY INJURIES OR DEATH.
  • Page 14 AC outlet, the device will accept power from the external power source and replenish the battery. It is not mandatory for the battery to be installed for the Eclipse 5 to operate. Proper connection of the AC or DC Power Supply requires aligning the power plug with the recessed external power receptacle of the device.
  • Page 15 When the Eclipse 5 is connected to the DC supply Settings Available When Operating on DC for in a vehicle, the following applies: Eclipse 5 • The Eclipse 5 is able to run at all continuous flow Flow Setting Bolus Size Continuous Pulse settings up to 3.0LPM and all pulse flow settings...
  • Page 16 Initial Battery Charging until it locks (clicks) into position and is flush with The new Battery supplied with your Eclipse 5 is not the back of the device. When the Battery is properly fully charged when it is shipped from the factory.
  • Page 17 Battery suf- discharged, during an AC power interruption, the ficiently cools. Removing the Battery and allowing Eclipse 5 will shut down and alarm. The Battery is it to cool may expedite this cooling process. fully discharged when the Power Cartridge Status...
  • Page 18 Eclipse 5. If the air inlet filter is missing, contact nasal cannula in your nose is critical to the amount your home care provider. If the air inlet filter is...
  • Page 19 LOX0010) available on www.CAIREmedical.com. Max Breath Rate A firebreak is required for use with any cannula. AC Power • CAIRE offers the OxySafe™. This is intended to be Bolus Supply & used in conjunction with the oxygen concentrator. DC Power...
  • Page 20 Eclipse 5 seconds to power OFF your Eclipse 5. to the device. Store the Eclipse 5 in a cool and dry location for a Depress the push-button on the Universal Cart handle to adjust period no longer than 1 month. The Eclipse 5 must run for a minimum of 2 hours per month to ensure the height of the handle.
  • Page 21 Eclipse 5 Alarms Table Alarm LCD Text Green Yellow Audio Code All OK, warm-up done NO ALARM Warm-up O2 < 85% O2 LOW No Beeps No breath detected (less than NO ALARM 45 seconds) No breath detected (exceeding P <--> C...
  • Page 22 - There will be a green light on the power supply box. DC power supply power supply. - There will be a green light on the Eclipse 5 concentrator control panel in the shape of a power cord. 4) If power verification LEDs are not lit, remove all connections of the power supply for 20 seconds and reconnect.
  • Page 23 1) Remove power cartridge and re-install to ensure that it is secure in the concentrator. 2) Inspect the Eclipse 5 for a solid yellow light when the battery is The Eclipse 5 is not installed, or a flashing battery icon when attempting to charge.
  • Page 24: Routine Maintenance

    CAUTION: Do not operate the Oxygen Servicing of the internal components inside the Concentrator without the air intake cabinet of the Eclipse 5 must be conducted by a filter in place. If a second filter is pro- CAIRE trained and qualified service technician as vided, insert the “replacement”...
  • Page 25 TECHNICIAN SHOULD REMOVE THE COVERS OR Before cleaning the Universal Cart, remove it from SERVICE THE UNIT. the Eclipse 5. Use a damp (not wet) cloth or sponge and mild detergent solution to clean the Universal WARNING: CARE SHOULD BE TAKEN TO PRE- Cart.
  • Page 26 EMC information provided in this section. Guidance and Manufacturer’s Declaration —Electromagnetic Emissions The Eclipse 5 is intended for use in the electromagnetic environment specified below. The customer or the user of the Eclipse 5 should assure that it is used in such an environment.
  • Page 27 Eclipse 5 Guidance and Manufacturer’s Declaration—Electromagnetic Immunity The Eclipse 5 is intended for use in the electromagnetic environment specified below. The customer or the user of the Eclipse 5 should assure that it is used in such an environment. Immunity test Compliance level Electromagnetic environment –...
  • Page 28 Eclipse 5 NOTES: 28 - ENG PN 21182453 C | User Manual...
  • Page 29 Eclipse 5 NOTES: PN 2118245 C | User Manual 29 - ENG...
  • Page 30 Eclipse 5 NOTES: 30 - ENG PN 21182453 C | User Manual...
  • Page 31 Eclipse 5 and use the aircraft supplemental oxygen. Continuous Flow FLIGHT LENGTH (in Hrs)* The Eclipse 5 unit is to be turned off after securing 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 the aircraft supplemental oxygen. 0.5 1 Prior to travel, the user needs to inspect the Eclipse 1.0 1...
  • Page 32 Medical Product Service GmbH Borngasse 20 35619 Braunfels, Germany SeQual , Eclipse 5 and autoSAT are trademarks of CAIRE Inc., Ball Ground, GA 30107 ® ® ® Salter Labs is a registered mark of Salter Labs, Arvin, CA 92303 ®...