Lippert Components LCI Level-Up Owner's Manual page 14

Motorhome leveling
Hide thumbs Also See for LCI Level-Up:
Table of Contents

Advertisement

What Is Happening?
System will not turn on
and On/Off indicator
light does not illuminate.
Control panel turns on
but turns off when jack
button is pushed or
displays "Low Voltage."
Control panel turns on,
coach will not auto level,
"Jacks Down" displayed,
jacks are retracted.
Jacks will not extend
to ground, pump is
running.
Any one or two jacks will
not retract.
"Jacks Retracted" does
not display when all
jacks are retracted.
Alarm sounds and
"Jacks Down" light starts
flashing while traveling,
jacks are fully retracted.
Jack bleeds down after
being extended.
Control panel powers
up, screen displays "Low
Voltage."
No power to control
panel
Auto level function does
not finish
Rev: 06.29.18
Why?
Coach ignition not in
RUN position.
Parking brake not set.
Controls have been
on for more than four
minutes and have timed
out.
Low voltage on battery.
Low fluid level.
Little to no fluid in
reservoir.
Leg valve is inoperative.
Electronic signal is lost
between control and
leg valves.
Hose damaged or
unconnected.
Valve inoperative.
Electronic signal is lost
between control and
solenoid.
Low fluid level.
Retract press switch
inoperable.
Low fluid level.
Retract press switch
inoperable.
Valve Manual Override
open.
Engine not running.
Tripped circuit breaker.
Ignition not ON.
Error code "Unable to
Finish Leveling".
What Should Be Done?
Turn ignition to RUN position.
Set parking brake.
Turn ignition OFF and then back ON.
Start coach to charge battery.
Change fluid level in reservoir. If fluid is low, add
fluid to ½" from top of reservoir with jacks retracted.
If JACKS DOWN light remains on, call Lippert Service.
Add fluid as recommended. See Page 13.
Clean, repair or replace.
Trace wires for voltage drop or loss of signal. Repair
or replace necessary wires or replace control pad.
Replace with new hose or reconnect hose.
Replace inoperative valve.
Attempt to retract jacks in MANUAL mode. If
successful, replace control pad. If not, test for voltage
drop between control pad and leg valve. Repair bad
wiring or replace defective board or valve.
Add fluid as recommended. See Page 13.
Check connection or replace.
Add fluid as recommended. See Page 13.
Check connection or replace.
Close override. See Page 12, Fig. 8.
Start coach engine.
Reset.
Turn ignition ON.
Move coach to a more level site.