DWFS4 MAXI BURNER FOR RESIDENTIAL AND PROFESSIONAL USE INSTRUCTIONS for installation and use...
Page 2
14. In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry out any repairs, which must be done exclusively by an authorized service center. Request the use of original spare parts only. Failure to comply with the above recommendations may compromise the appliance’s safety Officine Gullo...
Page 3
Raccord gaz Data Plate Gas Connection Chapa de características Conexión gas A. Data plate etta caratteristiche Attacco gas nschild Gasanschluss B. Gas Connection ISO 7-1 R1/2GM e des caractéristiques Raccord gaz Plate Gas Connection a de características Conexión gas Officine Gullo...
Page 4
BY-PASS FIG.C FIG.C Injector cooking rings Air regulation Pilot Wok ring Iniettore fuochi Einspritzventil flamme Injecteur feux Injector cooking rings Inyector fuegos Officine Gullo Regolazione aria Luftregelung Réglage d'air Air regulation Regulación aire Gruppo pilota ZündBrenner Veilleuse Pilot Piloto...
Page 5
FIG.D Pilot bracket screw Pilot bracket Pilot air bush Pilot Injector Injector screw Spring Thermocouple Officine Gullo...
CLEANING AND MAINTENANCE ............13 WHAT TO DO IN THE EVENT OF A BREAKDOWN......14 PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME ..........14 INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS ....15 Officine Gullo...
Gas coupling MODEL 7 kW 10 kW Tot. kW ISO 7-1 DWFS4 40 x 70 x 29h R 1/2”GM INSTALLATION • The operations for installing, conversions for use with other types of gas and starting up must be done only by qualified personnel whose qualifications comply with the norms in force.
Take suitable measures to guarantee thermal insulation of the inflammable sides, such as, for example, the installation of protection against radiation. The appliances must be installed in a suitable manner, observing the safety standards. The small feet are adjustable to level the appliance. Officine Gullo...
Connection with natural gas H G20 The connection pressure for natural gas is 20 mbar. Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied by the manufacturer. Officine Gullo...
Once regulated, tighten the screw, adjust the minimum flame by turning the screw to the right or left until the thermal power reaches 2.3 kW for the 10 kW burner. Caution: If liquid gas is being used the minimum adjustment screw must be locked right down.. Officine Gullo...
ANELLO WOK L’apparecchio va usato solamente con questo accessorio, applicato sopra la The device is usually used with this accessory, which is applied above L’apparecchio va usato solamente con questo accessorio, applicato sopra la griglia griglia the grill. Officine Gullo...
It is recommended that the metal be rubbed, uniformly applying light pressure, until the desired effect is achieved. The brass details should then be dried. Do not use polish as this is suitable for maintaining the gloss but not the antique finish and Officine Gullo...
Turn off the gas tap and notify the after sales service. PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME Turn off the gas tap and clean the appliance as specified above. Officine Gullo...
4.3 of the UNI-CIG norm 8723. Supplying the appliance with gas again must only be possible manually. NATURAL DISCHARGE FORCED DISCHARGE Fig.1 Fig.2 1. Extractor hood 1. Extractor hood 2. Interlocking Officine Gullo...