LOC
PAGE OUTPUT
41
234
5
235
5
42
236
5
43
237
5
44
238
5
45
5
46
239
5
47
240
48
241
5
USE THE FOLLOWING TABLE FOR
EVEN NUMBERED LOCATIONS 242 – 336
(EVENT / TIME)
#
Event
0
Always On
AC Fail (control or exp.) does
1
not follow AC Fail delay time
2
Low Battery (control or exp.)
3
Dynamic Battery Test Time
4
Listen In
5
Line Seizure
6
Telephone Line Fault
7
Program Mode
8
Over-current (control or exp.)
9
Box Tamper (control or exp.)
10
Siren Tamper (control or exp.)
11
Smoke Power Reset
12
Yelping Siren
29
13
Steady Siren
30
14
Any Siren
31
15
Steady Siren (temporal)
32
16
Any Siren (temporal)
LOC
PAGE
242
6
EVENT / TIME – OUTPUT 1
6
FEATURES – OUTPUT 1
243
244
6
EVENT / TIME – OUTPUT 2
6
FEATURES – OUTPUT 2
245
246
6
EVENT / TIME – OUTPUT 3
247
6
FEATURES – OUTPUT 3
6
EVENT / TIME – OUTPUT 4
248
249
6
FEATURES – OUTPUT 4
250
6
EVENT / TIME – OUTPUT 5
251
6
FEATURES – OUTPUT 5
252
6
EVENT / TIME – OUTPUT 6
6
FEATURES – OUTPUT 6
253
254
6
EVENT / TIME – OUTPUT 7
255
6
FEATURES – OUTPUT 7
6
EVENT / TIME – OUTPUT 8
256
257
6
FEATURES – OUTPUT 8
6
EVENT / TIME – OUTPUT 9
258
259
6
FEATURES – OUTPUT 9
260
6
EVENT / TIME – OUTPUT 10
6
FEATURES – OUTPUT 10
261
262
6
EVENT / TIME – OUTPUT 11
6
FEATURES – OUTPUT 11
263
264
6
EVENT / TIME – OUTPUT 12
265
6
FEATURES – OUTPUT 12
6
EVENT / TIME – OUTPUT 13
266
267
6
FEATURES – OUTPUT 13
6
EVENT / TIME – OUTPUT 14
268
269
6
FEATURES – OUTPUT 14
270
6
EVENT / TIME – OUTPUT 15
6
FEATURES – OUTPUT 15
271
272
6
EVENT / TIME – OUTPUT 16
6
FEATURES – OUTPUT 16
273
14
PROGRAMMING NODE INFORMATION FOR OUTPUTS 1 - 48
Segment #1
Physical address
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
#
Event
17
Alarm Memory
18
Entry
19
Exit
20
Entry or Exit
21
Armed
22
Disarmed
23
Ready to Arm
24
Not Ready to Arm
25
Fire
26
Fire Trouble
27
Chime
28
Beeping Keypad
Aux 1 Keypad Function
Aux 2 Keypad Function
Panic Keypad Function
Code Entry ( locs 338 - 481)
DESCRIPTION
NX-2192E PINPOINT SYSTEM
Segment #2
Output number
1 _ _ _ _ _ _ _
1 _ _ _ _ _ _ _
1 _ _ _ _ _ _ _
1 _ _ _ _ _ _ _
1 _ _ _ _ _ _ _
1 _ _ _ _ _ _ _
1 _ _ _ _ _ _ _
1 _ _ _ _ _ _ _
USE THE FOLLOWING TABLE FOR
ODD NUMBERED LOCATIONS 243 – 337
SEG 1
DESCRIPTION
1 =
ON times in minutes
OFF if times in seconds
2 =
ON to latch until a code is
entered; OFF for timed
3 =
ON if output should stop time
when a code is entered
4 =
ON for inverted output
5 =
ON disables output during
listen-in (only events 12-16)
6 =
Reserved
7 =
Reserved
8 =
Reserved
SEG 1 DEFAULT
SEG 1 DATA
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
14=Any Siren
_ _ _ _ _ _ _ _
Segment #3
Error code
_
_
_
_
_
_
_
_
(SPECIAL FEATURES)
SEG 2
DESCRIPTION
1 =
On if event activates output in
Partition 1
2 =
On if event activates output in
Partition 2
3 =
On if event activates output in
Partition 3
4 =
On if event activates output in
Partition 4
5 =
On if event activates output in
Partition 5
6 =
On if event activates output in
Partition 6
7 =
On if event activates output in
Partition 7
8 =
On if event activates output in
Partition 8
SEG 2 DEFAULT
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
0=Follow Evt
1 2 3 4 5 6 7 8
Notes
SEG 2 DATA
Need help?
Do you have a question about the NetworX NX-2192E-EUR and is the answer not in the manual?