GE Interlogix NetworX NX-2192E-EUR Installation Manual

Pinpoint system

Advertisement

1.
GENERAL DESCRIPTION.......................................................................................................................... 2
2.
INSTALLATION .......................................................................................................................................... 2
3.
DEVICE ADDRESS CONFIGURATION...................................................................................................... 2
4.
TERMINAL DESCRIPTIONS ...................................................................................................................... 2
5.
WIRING DIAGRAM ..................................................................................................................................... 3
6.
MAXIMUM NUMBER OF DEVICES PER WIRE RUN ................................................................................ 4
7.
ENROLLING THE PINPOINT SYSTEM...................................................................................................... 4
8.
PROGRAMMING THE MODULE................................................................................................................ 4
9.
PROGRAMMING SEQUENCE EXAMPLE ................................................................................................. 4
10.
PROGRAMMING LOCATION GUIDE ........................................................................................................ 5
11.
BATTERY CALCULATION WORKSHEET................................................................................................. 8
12.
NX-2192E PROGRAMMING WORKSHEETS ............................................................................................ 9
13.
14.
UL & CE NOTICES ................................................................................................................................... 44
15.
SPECIFICATIONS..................................................................................................................................... 44
© 2003 GE Interlogix
All rights reserved. Printed in the USA.
NetworX is a trademark of the GE Interlogix companies.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met during
installation, operation, and maintenance. If further information is desired or if particular problems arise that are not covered sufficiently for the
purchaser's purpose, the matter should be referred to GE Interlogix, Gladewater, Texas, USA.
This document contains proprietary information of GE Interlogix, USA and is furnished to its customer solely to assist that customer in the installation,
testing, operations, and/or maintenance of the equipment described. This document shall not be reproduced in whole or in part nor shall its contents
be disclosed to any third party without the written approval of GE Interlogix. Please refer to the current GE Interlogix product catalog for detailed
warranty information.
NX-2192E PINPOINT SYSTEM
INSTALLATION MANUAL
PINPOINT ADDRESS WORKSHEET............................................................................. 40
Main
800-727-2339
Outside the US
903-845-6941
Main Fax
903-845-6811
Web:
www.caddx.com

TABLE OF CONTENTS

1420 N. Main
Gladewater, TX 75647
Technical Support 800-727-2339
Tech Support Fax 903-845-8409
Sales & Literature 800-547-2556
www.ge-interlogix.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NetworX NX-2192E-EUR and is the answer not in the manual?

Questions and answers

Summary of Contents for GE Interlogix NetworX NX-2192E-EUR

  • Page 1: Table Of Contents

    This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without the written approval of GE Interlogix. Please refer to the current GE Interlogix product catalog for detailed warranty information.
  • Page 2: General Description

    GENERAL DESCRIPTION The NX-2192E is a microprocessor-controlled point ID bus interface module for the NX-8E control panel. The PinPoint System provides two-wire bidirectional communications with up to 255 individually addressed devices. The total number of devices in a system is limited by the I/O capability of the panel.
  • Page 3: Wiring Diagram

    WIRING DIAGRAM NX-2192E PINPOINT SYSTEM...
  • Page 4: Maximum Number Of Devices Per Wire Run

    MAXIMUM NUMBER OF DEVICES PER WIRE RUN The number of devices on an individual wire run must not exceed the number listed in the following table. If a star configuration is used, the total wire length must not exceed 10000 feet per loop output. Table 6-1 Wire Length in Feet...
  • Page 5: Programming Location Guide

    10. PROGRAMMING LOCATION GUIDE POINT ID PROGRAM MODE LOCATION 0 16 segments of numerical data DESIGNATION Location 0 is used to communicate to the PID bus interface to enter PID Program Mode. Segment 1 must be set to [1] to “learn” points. While in this mode, all nodes able to communicate will be enabled and mapped to pre- programmed zones.
  • Page 6 Table 10-2 ERROR CODE DESCRIPTION Node is missing. Multiple node responded. Communication error. Device type mismatch. Auto enroll error. Reserved. Output programmed to non-output device. Output programmed but node not enabled. EVENT & TIME FOR LOCATION 242 – 336 (EVEN LOC) 2 segments of numerical data OUTPUTS 1 - 48 Segment 1 is used to select the particular event that will trigger the output.
  • Page 7 Table 10-4 DESCRIPTION OUTPUTS "On" if code will activate output; "Off" if it will not. 1, 9, 17, 25, 33, 41 TABLE 10-4 "On" if code will activate output; "Off" if it will not. 2, 10, 18, 26, 34, 42 IS USED TO "On"...
  • Page 8: Battery Calculation Worksheet

    11. BATTERY CALCULATION WORKSHEET TOTAL STANDBY CURRENT System Component Standby Current TOTAL STANDBY CURRENT NX-8E-CF 60mA 60mA NX-870E 20mA 20mA NX-148E 75mA NX-208E Aux+ 13mA NX-216E 30mA NX-320E 10mA NX-507E 10mA NX-1700E 40mA NX-2192E 170mA TOTAL TOTAL ALARM CURRENT System Component Device Alarm Current TOTAL ALARM CURRENT NX-8E-CF...
  • Page 9: Nx-2192E Programming Worksheets

    12. NX-2192E Programming Worksheets (Defaults are printed in bold italics text.) PAGE DESCRIPTION PROGRAM MODE DESIGNATION (Segement 1 must be set to [1] in order to ‘learn’ points) PROGRAMMING NODE INFORMATION FOR ZONES 1 - 192 Segment #1 Segment #2 Segment #3 PAGE Notes...
  • Page 10 PROGRAMMING NODE INFORMATION FOR ZONES 1 - 192 Segment #1 Segment #2 Segment #3 PAGE Notes Physical address Input number Error code 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _...
  • Page 11 PROGRAMMING NODE INFORMATION FOR ZONES 1 - 192 Segment #1 Segment #2 Segment #3 PAGE Notes Physical address Input number Error code 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _...
  • Page 12 PROGRAMMING NODE INFORMATION FOR ZONES 1 - 192 Segment #1 Segment #2 Segment #3 PAGE Notes Physical address Input number Error code 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _...
  • Page 13 PAGE DESCRIPTION DEVICE OPTIONS Reserved. "On" if Loop A should be enabled; “Off” if disabled. "On" if Loop B should be enabled; “Off” if disabled. "On" if Loop C should be enabled; “Off” if disabled. “On” if 24V mode; “Off” if 12V mode. “On”...
  • Page 14: Event / Time – Output

    PROGRAMMING NODE INFORMATION FOR OUTPUTS 1 - 48 Segment #1 Segment #2 Segment #3 PAGE OUTPUT Notes Physical address Output number Error code 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 1 _ _ _ _ _ _ _...
  • Page 15 PAGE DESCRIPTION SEG 1 DEFAULT SEG 1 DATA SEG 2 DEFAULT SEG 2 DATA EVENT / TIME – OUTPUT 17 14=Any Siren 0=Follow Evt FEATURES – OUTPUT 17 _ _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 EVENT / TIME –...
  • Page 16: Event / Time – Output

    PAGE DESCRIPTION SEG 1 DEFAULT SEG 1 DATA SEG 2 DEFAULT SEG 2 DATA EVENT / TIME – OUTPUT 48 14=Any Siren 0=Follow Evt FEATURES – OUTPUT 48 _ _ _ _ _ _ _ _ 1 2 3 4 5 6 7 8 PAGE DESCRIPTION CODES 1-10 OUTPUT SELECTION (Circle the numbers to disable)
  • Page 17 PAGE DESCRIPTION CODES 61-70 OUTPUT SELECTION (Circle the numbers to disable) User Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 CODES 71-80 OUTPUT SELECTION (Circle the numbers to disable) User Output 1 Output 2 Output 3 Output 4...
  • Page 18 PAGE DESCRIPTION CODES 121-130 OUTPUT SELECTION (Circle the numbers to disable) User Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 CODES 131-140 OUTPUT SELECTION (Circle the numbers to disable) User Output 1 Output 2 Output 3 Output 4...
  • Page 19 PAGE DESCRIPTION CODES 181-190 OUTPUT SELECTION (Circle the numbers to disable) User Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 CODES 191-200 OUTPUT SELECTION (Circle the numbers to disable) User Output 1 Output 2 Output 3 Output 4...
  • Page 20 PAGE DESCRIPTION CODES 1-10 OUTPUT SELECTION (Circle the numbers to disable) User Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 CODES 11-20 OUTPUT SELECTION (Circle the numbers to disable) User Output 9 Output 10 Output 11 Output 12...
  • Page 21 PAGE DESCRIPTION CODES 61-70 OUTPUT SELECTION (Circle the numbers to disable) User Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 CODES 71-80 OUTPUT SELECTION (Circle the numbers to disable) User Output 9 Output 10 Output 11 Output 12...
  • Page 22 PAGE DESCRIPTION CODES 121-130 OUTPUT SELECTION (Circle the numbers to disable) User Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 CODES 131-140 OUTPUT SELECTION (Circle the numbers to disable) User Output 9 Output 10 Output 11 Output 12...
  • Page 23 PAGE DESCRIPTION CODES 181-190 OUTPUT SELECTION (Circle the numbers to disable) User Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 CODES 191-200 OUTPUT SELECTION (Circle the numbers to disable) User Output 9 Output 10 Output 11 Output 12...
  • Page 24 PAGE DESCRIPTION CODES 1-10 OUTPUT SELECTION (Circle the numbers to disable) User Output 17 Output 18 Output 19 Output 20 Output 21 Output 22 Output 23 Output 24 CODES 11-20 OUTPUT SELECTION (Circle the numbers to disable) User Output 17 Output 18 Output 19 Output 20...
  • Page 25 PAGE DESCRIPTION CODES 61-70 OUTPUT SELECTION (Circle the numbers to disable) User Output 17 Output 18 Output 19 Output 20 Output 21 Output 22 Output 23 Output 24 CODES 71-80 OUTPUT SELECTION (Circle the numbers to disable) User Output 17 Output 18 Output 19 Output 20...
  • Page 26 PAGE DESCRIPTION CODES 121-130 OUTPUT SELECTION (Circle the numbers to disable) User Output 17 Output 18 Output 19 Output 20 Output 21 Output 22 Output 23 Output 24 CODES 131-140 OUTPUT SELECTION (Circle the numbers to disable) User Output 17 Output 18 Output 19 Output 20...
  • Page 27 PAGE DESCRIPTION CODES 181-190 OUTPUT SELECTION (Circle the numbers to disable) User Output 17 Output 18 Output 19 Output 20 Output 21 Output 22 Output 23 Output 24 CODES 191-200 OUTPUT SELECTION (Circle the numbers to disable) User Output 17 Output 18 Output 19 Output 20...
  • Page 28 PAGE DESCRIPTION CODES 1-10 OUTPUT SELECTION (Circle the numbers to disable) User Output 25 Output 26 Output 27 Output 28 Output 29 Output 30 Output 31 Output 32 CODES 11-20 OUTPUT SELECTION (Circle the numbers to disable) User Output 25 Output 26 Output 27 Output 28...
  • Page 29 PAGE DESCRIPTION CODES 61-70 OUTPUT SELECTION (Circle the numbers to disable) User Output 25 Output 26 Output 27 Output 28 Output 29 Output 30 Output 31 Output 32 CODES 71-80 OUTPUT SELECTION (Circle the numbers to disable) User Output 25 Output 26 Output 27 Output 28...
  • Page 30 PAGE DESCRIPTION CODES 121-130 OUTPUT SELECTION (Circle the numbers to disable) User Output 25 Output 26 Output 27 Output 28 Output 29 Output 30 Output 31 Output 32 CODES 131-140 OUTPUT SELECTION (Circle the numbers to disable) User Output 25 Output 26 Output 27 Output 28...
  • Page 31 PAGE DESCRIPTION CODES 181-190 OUTPUT SELECTION (Circle the numbers to disable) User Output 25 Output 26 Output 27 Output 28 Output 29 Output 30 Output 31 Output 32 CODES 191-200 OUTPUT SELECTION (Circle the numbers to disable) User Output 25 Output 26 Output 27 Output 28...
  • Page 32 PAGE DESCRIPTION CODES 1-10 OUTPUT SELECTION (Circle the numbers to disable) User Output 33 Output 34 Output 35 Output 36 Output 37 Output 38 Output 39 Output 40 CODES 11-20 OUTPUT SELECTION (Circle the numbers to disable) User Output 33 Output 34 Output 35 Output 36...
  • Page 33 PAGE DESCRIPTION CODES 61-70 OUTPUT SELECTION (Circle the numbers to disable) User Output 33 Output 34 Output 35 Output 36 Output 37 Output 38 Output 39 Output 40 CODES 71-80 OUTPUT SELECTION (Circle the numbers to disable) User Output 33 Output 34 Output 35 Output 36...
  • Page 34 PAGE DESCRIPTION CODES 121-130 OUTPUT SELECTION (Circle the numbers to disable) User Output 33 Output 34 Output 35 Output 36 Output 37 Output 38 Output 39 Output 40 CODES 131-140 OUTPUT SELECTION (Circle the numbers to disable) User Output 33 Output 34 Output 35 Output 36...
  • Page 35 PAGE DESCRIPTION CODES 181-190 OUTPUT SELECTION (Circle the numbers to disable) User Output 33 Output 34 Output 35 Output 36 Output 37 Output 38 Output 39 Output 40 CODES 191-200 OUTPUT SELECTION (Circle the numbers to disable) User Output 33 Output 34 Output 35 Output 36...
  • Page 36 PAGE DESCRIPTION CODES 1-10 OUTPUT SELECTION (Circle the numbers to disable) User Output 41 Output 42 Output 43 Output 44 Output 45 Output 46 Output 47 Output 48 CODES 11-20 OUTPUT SELECTION (Circle the numbers to disable) User Output 41 Output 42 Output 43 Output 44...
  • Page 37 PAGE DESCRIPTION CODES 61-70 OUTPUT SELECTION (Circle the numbers to disable) User Output 41 Output 42 Output 43 Output 44 Output 45 Output 46 Output 47 Output 48 CODES 71-80 OUTPUT SELECTION (Circle the numbers to disable) User Output 41 Output 42 Output 43 Output 44...
  • Page 38 PAGE DESCRIPTION CODES 121-130 OUTPUT SELECTION (Circle the numbers to disable) User Output 41 Output 42 Output 43 Output 44 Output 45 Output 46 Output 47 Output 48 CODES 131-140 OUTPUT SELECTION (Circle the numbers to disable) User Output 41 Output 42 Output 43 Output 44...
  • Page 39 PAGE DESCRIPTION CODES 181-190 OUTPUT SELECTION (Circle the numbers to disable) User Output 41 Output 42 Output 43 Output 44 Output 45 Output 46 Output 47 Output 48 CODES 191-200 OUTPUT SELECTION (Circle the numbers to disable) User Output 41 Output 42 Output 43 Output 44...
  • Page 40: Appendix 1 Pinpoint Address Worksheet

    13. Appendix 1 PinPoint Address Worksheet Zone Installation Location Device Type Address Switch Setting Address Number _ _ _ _ _ _ _ _ 1 _ _ _ _ _ _ _ _ 2 _ _ _ _ _ _ 1 2 _ _ _ _ _ _ _ _ 3 _ _ _ _ _ 1 _ 3_ _ _ _ _...
  • Page 41 Zone Installation Location Device Type Address Switch Setting Address Number _ _ _ _ _ _ 7 _ 1 _ _ _ _ _ 7 _ _ 2 _ _ _ _ 7 _ 1 2 _ _ _ _ 7 _ _ _ 3 _ _ _ 7 _ 1 _ 3_ _ _ 7 _ _ 2 3 _ _ _ 7 _...
  • Page 42 Zone Installation Location Device Type Address Switch Setting Address Number _ 2 _ _ _ _ _ 8 1 2 _ _ _ _ _ 8 _ _ 3 _ _ _ _ 8 1 _ 3_ _ _ _ 8 _ 2 3 _ _ _ _ 8 1 2 3 _ _ _ _ 8 _ _ _ 4 _ _ _ 8...
  • Page 43 Zone Installation Location Device Type Address Switch Setting Address Number 1 _ 3_ _ _ 7 8 _ 2 3 _ _ _ 7 8 1 2 3 _ _ _ 7 8 _ _ _ 4 _ _ 7 8 1 _ _ 4 _ _ 7 8 _ 2 _ 4 _ _ 7 8 1 2 _ 4 _ _ 7 8...
  • Page 44: Ul & Ce Notices

    Household Fire Warning Systems & Units Manufacturer: GE Interlogix UL1023 Household Burglary Alarm Systems & Units 1420 N Main; Gladewater, TX 75647 USA GE Interlogix B.V. UL1610 Grade B & C Central Station Burglar Alarm Unit Representative UL1635 Digital Alarm Communicator System Units...

This manual is also suitable for:

Networx nx-2192e

Table of Contents