Plug And Connection Assignments - Ignition Xo8 LED Fx Strobe User Manual

Ip65 800w
Table of Contents

Advertisement

Plug and connection assignments

9
Plug and connection assignments
Introduction
DMX connections
Xo8 LED Fx Strobe IP65 800W
28
stroboscope
This chapter will help you select the right cables and plugs to connect your valuable
equipment so that a perfect light experience is guaranteed.
Please take our tips, because especially in 'Sound & Light' caution is indicated: Even if
a plug fits into a socket, the result of an incorrect connection may be a destroyed
DMX controller, a short circuit or 'just' a not working light show!
The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX
input. Please refer to the drawing and table below for the pin assignment of a suit-
able XLR plug.
Pin
Configuration
1
Ground, shielding
2
Signal inverted (DMX–, 'cold signal')
3
Signal (DMX+, 'hot signal')