Do you have a question about the 14029 and is the answer not in the manual?
Questions and answers
Michael Frederick Brashear
June 25, 2025
My wife's mattress will randomly go off and the alarm will beep. If I turn it off and wait a few minutes and tur times for only a few minutes before it shuts off again. What could be rthe problem?
IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following: READ ALL INTRUCTIONS BEFORE USING DANGER To reduce the risk of electrocution: Always unplug this product immediately after use. Do not use while bathing.
STATEMENTS & SYMBOLS Note, caution, warning & danger statements NOTE Indicates some tips or some information users should be aware of. CAUTION Indicates correct operating or maintenance procedure in order to prevent damage to or destruction of the equipment or other property. W ARNING/DANGER Calls attention to a potential danger that requires correct procedures or practices in order to prevent personal injury.
The Med Aire series has been tested and certified for the following standards: UL 60601 Intended Use The 14029 & 14030 series is intended to reduce the incidence of pressure ulcers while optimizing patient comfort. It also provides the following: Individual home care setting and long-term care Pain management as prescribed by a physician.
Always read this manual before using this product. PRODUCT FUNCTIONS Pump Unit The functions of the pump unit for the 14029 series are described below. Please refer to the figures of each type. Power Switch: The switch is at the right side of the unit.
Auto firm: Sets the air mattress to auto-inflation mode. Mattress System The 14029 series comes with cell type mattresses of different materials, provided optionally with the pump unit. The mattress options for the 14029 series are Nylon/PVC, Nylon/PU or PU.
Step 2 Cover with a cotton sheet to avoid direct skin contact and reduce friction. Step 3 Hang the pump unit on the foot end of the bed frame and make sure it is stable. Step 4 Connect the inflation tubes from the mattress to the pump’s inflating nozzles. Make sure they are properly attached.
AHCPR. Please follow instructions below for detailed operating procedure of each type. 14029/14030 Step 1 Turn on the power. A beep sound will begin the operation. Step 2 These two types will enter static mode initially when the power is turned on.
First it will inflate the mattress to 30mm Hg and then enter alternating mode. If 30mm Hg cannot be reached within 30 minutes, the unit will stay in static mode and keep inflating. If 30mm Hg still cannot be reached within another 15 minutes, the alarm will beep and its LED will come on.
Low pressure When abnormal pressure occurs, the Low Pressure LED will come on. For some types of pumps, the alarm will be activated to alert of a low pressure condition. Check if the connections are secure and correctly installed according to the relevant instructions. NOTE: If the pressure is consistently low, check for any leakage (tubes or connecting hoses).
sides, including all the connecting tubes and hoses. Let it sit for least 10 minutes. ) If there is a base after you remove all the air cells, the base has to be sprayed down with the disinfectant, inside and outside. Let it sit for the required incubation time and wipe down with a cloth.
SPECIFICATIONS System Item Specifications Power Supply AC 120V/60Hz, 10W Pressure Range 30 ~ 60 mmHg 14029 10 ~ 70 mmHg 14030 Cycle Time 10 min/60Hz 14029/14030 26.0 × 13.0 × 8.0 cm Dimensions 10.2 x 5.1 x 3.1 in Weight 1.5 kg...
Page 14
The above specifications are also applicable to those areas operating with the same power supply range. Pump Unit Series Function Specifications Dimension: 33.4 × 12.0 × 24.6 cm 14029 ON/OFF switch Pressure-selector knob 13.1 x 4.7 x 9.7 in Normal Pressure LED Power: 230V AC/50Hz, 120V AC/60Hz Low Pressure LED...
Need help?
Do you have a question about the 14029 and is the answer not in the manual?
Questions and answers
My wife's mattress will randomly go off and the alarm will beep. If I turn it off and wait a few minutes and tur times for only a few minutes before it shuts off again. What could be rthe problem?