Robertshaw 9701i2 Quick Start Installation Manual

Robertshaw 9701i2 Quick Start Installation Manual

Deluxe programmable thermostats

Advertisement

Quick Links

DELUXE
1
Select location for installation.
PROGRAMMABLE
1"
THERMOSTATS
Quick Start Installation Manual
Cut
Models 9701i2 and 9725i2
1-1/2"
out
opening
1/2"
Remove 1/2" of insulation
from end of each wire
110-1180
Installation DOs and DON'Ts
8
Connect wiring between the thermostat and
equipment. For Model 9725i2 (2 heat / 2 cool;
DO
gas / electric).
• Shut off all power to system before installing.
Thermostat

TERMINAL DESIGNATIONS

• Read entire manual before installing.
C
- 24VAC Common
• Make sure that all wiring conforms to
C
R
- 24VAC
R
national and local codes.
Y1
Y1
- 1st stage cooling
E/W1
E/W1 - 1st stage heating
W2
W2
- 2nd stage heating
Y2
L
Y2
- 2nd stage cooling
DO NOT
L
- Not used
O B G
9725
2
O
- Not used
• Install on voltages greater than 30 VAC.
i
B
- Not used
• Short jumper across terminals on the gas
G
- Fan
valve or at the system control.
C
R
• Connect ground to any terminal in
Y1
W1
this unit.

Equipment Wiring Terminals

W2
• Install on outside walls or in direct sunlight.
Y2
Please refer to furnace
L
installation manual for
G
proper terminations
B
O
Set the time. Hours and minutes are
DELUXE
3
set separately. An AM/PM indicator
PROGRAMMABLE
automatically changes based on the
THERMOSTATS
hour chosen.

Setup Wizard Quick Start Guide

Press Next.
Set Time
The Setup Wizard allows you to quickly step
(Hour)
through the setup process. This guide
12:00
PM
shows a typical setup for a basic heating
system. The screens you see depend on
Back
Next
thermostat model and your heating/cooling
configuration.
Set the date.
4
First, set the month. Press Next.
NOTE: Use the
or
button to select a list
Then, set the day. Press Next.
item or to change the value of a number.
Finally, set the year. Press Next.
Use the gray buttons below the display to
Set Date
choose No, Yes, Back, Next, Next Char or
(Month)
Accept when appropriate.
1/1/05
Back
Next
Choose the time format – 12-hour
Selecting Yes allows you to go
5
1
clock or 24-hour clock.
through the setup process.
Press Next.
Would You Like
To Run the
Select Time Format
Setup Wizard?
12hr
24hr
No
Yes
Back
Next
Choose either English, Español, or
2
To activate the Auto Daylight Saving
Français as the display language.
6
Time feature, choose either:
This can always be changed after
Standard (April – October), or
the Setup Wizard is complete.
Extended (March – November).
Press Next.
Press Next.

Select Language

English
Auto Adjust For DST?
Español
No
Français
Standard (Apr-Oct)
Extended (Mar-Nov)
Back
Next
Back
Next
2
3
Open the case with a screwdriver. Place in slot
Mark mounting hole locations on wall.
and gently pry forward at all four locations.
a
b
2
1
3
4
9
10
Connect wiring between the thermostat and
Connect wiring between the thermostat and
equipment. For Model 9725i2 (2 heat / 2 cool;
equipment. For Model 9725i2 (2 heat / 2 cool;
heat pump with strip heat).
heat pump with furnace).
Thermostat
TERMINAL DESIGNATIONS
C
- 24VAC Common
C
R
- 24VAC
R
Y1
Y1
- 1st stage heating/cooling
E/W1
E/W1 - Emergency heat
W2
W2
- 2nd stage heating
Y2
L
Y2
- 2nd stage cooling
L
- System fault indicator
O B G
9725
2
O
- Cool active reversing valve
i
B
- Heat active reversing valve
G
- Fan
C
R
Y1
E
W2
Equipment Wiring Terminals
If terminal E is not
If terminal E is not
Y2
Please refer to heat pump
supplied, add
supplied, add
L
installation manual for
jumper across
proper terminations
jumper across
G
E/W1 and W2 on
E/W1 and W2 on
B
the thermostat.
the thermostat.
O
Select either the Fahrenheit or Celsius
Contact information can be entered
7
11
temperature scale.
at the factory. Talk to your
Press Next.
Robertshaw sales representative
about this feature.
Select Temperature
Scale
To edit information: Use the
°C
button to scroll through the character
°F
list. Press Next Char to move to the
Back
Next
to the next line, and finish editing.
Select the type of heating system that
8
will be used with the thermostat.
Press Next.
1st Stage Heat Equip
None
Furnace
Strip
Heat Pump
Back
Next
Auto changeover allows automatic
9
switching between heating and
cooling.
Make your selection. Press Next.
Enable
Auto Changeover?
No
Yes
Back
Next
Service reminders are available for:
10
Heat System, Heat Pump, Cool
System, Filter, UV Light and
Humidifier Pad. All can be set to OFF
or from 1 to 12 months.
Press Next.
Reminder To Service
Heat System In:
3
Mon
Back
Next
4
Drill 3/16" holes at marked locations on wall.
Insert plastic anchors into holes.
Drill 3 / 16 holes
a
Mark mounting hole
locations on wall using
b
unit base as template.
Press anchors into holes until flush.
11
Connect wiring between the thermostat and
equipment. For Model 9725i2 (2 heat / 2 cool;
2 stage heat pump with strip heat).
Thermostat
Thermostat
TERMINAL DESIGNATIONS
TERMINAL DESIGNATIONS
C
- 24VAC Common
C
- 24VAC Common
C
C
R
- 24VAC
R
- 24VAC
R
R
Y1
Y1
- 1st stage heating/cooling
Y1
Y1
- 1st stage heating/cooling
E/W1
E/W1
E/W1 - Emergency heat
E/W1 - Emergency heat (strip)
W2
W2
W2
- 2nd stage heating
W2
- 2nd stage heating
Y2
Y2
L
Y2
- 2nd stage cooling
L
Y2
- 2nd stage cooling
L
- System fault indicator
L
- System fault indicator
O B G
9725
2
O
- Cool active reversing valve
O B G
9725
2
O
- Cool active reversing valve
i
i
B
- Heat active reversing valve
B
- Heat active reversing valve
G
- Fan
G
- Fan
C
C
R
R
Y1
Y1
E
E
W2
Equipment Wiring Terminals
Equipment Wiring Terminals
W2
Y2
Please refer to heat pump
Please refer to heat pump
Y2
L
installation manual for
installation manual for
L
proper terminations
G
proper terminations
G
B
B
O
O
DELUXE
PROGRAMMABLE
THERMOSTATS

Operational Mode Chart

or
No 2nd
HVAC Mode
next character. Press Accept to move
Stage
is Emer
Set Contact Info
Outdoor
1st Stage
(Name)
Temperature
(2nd is na)
ABC HEATERS
123-555-2345
Next Char
Accept
< Low balance
E/W1
Between
E/W1
balance points
No sensor
3
Y1
E/W1
> High balance
E/W1
1. The 2nd stage is not used for heating when
the outdoor temperature is not between the
two balance points.
2. Standard and Add-On apply when the 2nd
stage is on. Y1 is either on (Standard) or off
(Add-On).
5
6
Align unit base over plastic anchors embedded
Connect wiring between the thermostat and
in wall and secure with the screws provided.
equipment. For Model 9701i2 (1 heat / 1 cool;
gas / electric).
Thermostat
O B G
12
13
Connect wiring between the thermostat and the
Replace cover on thermostat. Turn on power
indoor sensor (9020i) and the outdoor sensor
to unit and proceed with programming
(9025i), if used. Use twisted pair wiring (22AWG
per instructions on the display or in the
minimum) with a maximum length of 300 feet
user's manual.
(or 100m).
2nd Stage is
2nd Stage is a
2nd Stage is a Furnace
Strip
Heat Pump
Heat Pump
Standard
2
Add-On
2
Only
4
1st
2nd
1st
2nd
1st
2nd
1st
2nd
W2
na
1
W2
na
1
W2
na
1
E/W1
na
1
Y1 +
W2
Y1 +
Y1 +
Y1
Y1
Y1
Y1
W2
2
only
2
W2
2
W2
Y1 +
W2
Y1 +
Y1 +
Y1
Y1
Y1
Y1
W2
2
only
2
W2
2
W2
Y1
na
1
Y1
na
1
Y1
na
1
Y1
na
1
3. When no sensor is present, the thermostat
behaves as if the outdoor temperature is
always between the balance points.
4. Heat Pump Only applies to the 9725i2 when
it is configured as Heat Pump in both 1st and
2nd stage.
7
Connect wiring between the thermostat and
equipment. For Model 9701i2 (1 heat / 1 cool;
heat pump with strip heat [emergency]).
Thermostat
TERMINAL DESIGNATIONS
TERMINAL DESIGNATIONS
C
C
- 24VAC Common
C
- 24VAC Common
R
C
R
- 24VAC
R
Y1
R
- 24VAC
E/W1
Y1
- 1st stage cooling
Y1
Y1
- 1st stage heating/cooling
E/W1
E/W1 - 1st stage heating
E/W1 - Emergency heat
O
- Not used
O
- Cool active reversing valve
B
- Not used
B
- Heat active reversing valve
9701
2
G
- Fan
i
O B G
9701
2
G
- Fan
i
G
G
Equipment Wiring Terminals
Y1
Y1
Equipment Wiring Terminals
Please refer to furnace
R
R
Please refer to heat pump
installation manual for
E
W1
installation manual for
proper terminations
C
C
proper terminations
B
O
Recycling Thermostat
If this thermostat REPLACES a thermostat that contains mercury,
DO NOT discard the old thermostat in the regular trash. Mercury
is harmful to humans and the environment. For this reason, do
not open, break, or crush the mercury cell. If mercury leaks from
a damaged cell, DO NOT touch or handle mercury with bare
hands. Use protective, non-absorbent gloves to place mercury
into a sealable container. Fill the container with sand or another
absorbent material and seal the container completely.
Return the mercury or mercury products, in a sealed container, to
Invensys Climate Controls or a local recycling center for proper
disposal. If you have any questions, call Robertshaw technical
support at 1-800-445-8299.
In U.S.:
Invensys Controls Americas
28C Leigh Fisher Blvd.
El Paso, TX 79906
Attn: Mercury Recycling Center
In Canada:
Invensys Controls Americas
3515 Laird Road - Unit #14
Mississauga, Ontario L5L 5Y7
Attn: Mercury Recycling Center
NOTES:
NOTES:
Controls Americas
515 South Promenade Avenue
Corona, CA 92879-1736
United States of America
Made in U.S.A
www.about-i-series .com
110-1180