Download Print this page

Mitsubishi Electric FX3U-4HSX-ADP Installation Manual page 3

Fx3u series
Hide thumbs Also See for FX3U-4HSX-ADP:

Advertisement

JY997D16301E
Side
JAPANESE
A
Side
ENGLISH
B
FX
-4HSX-ADP
3U
INSTALLATION MANUAL
Manual Number
JY997D16301
Revision
E
Date
October 2017
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.
Effective October 2017
Specifications are subject to change without notice.
©
2005 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classify the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury or
physical damage.
Depending on circumstances, procedures indicated by
linked to serious results.
In any case, it is important to follow the directions for usage.
Associated Manuals
Manual name
Manual No.
Description
FX
Series
JY997D16501
E x p l a i n s F X
S e r i e s P L C
3U
3 U
User's Manual
MODEL
specification details for I/O, wiring,
- Hardware Edition
CODE: 09R516
installation, and maintenance.
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
FX
Series
JY997D16601
3UC
Describes PLC programming for
Programming Manual
MODEL
basic/applied instructions and
-
B a s i c
&
A p p l i e d
CODE: 09R517
devices.
Instruction Edition
How to obtain manuals
For the necessary product manuals or documents, consult with the Mitsubishi
Electric dealer from where you purchase your product.
Applicable Standard
FX
-4HSX-ADP complies with EC directive (EMC Directive) and UL standards
3U
(UL, cUL). Further information can be found in the following manual.
→ FX
Series Hardware Manual (Manual No. JY997D50301)
3U
Attention
This product is designed for use in industrial applications.
3. Used cables and Tightening Torque on Terminal
For connection example and wiring, refer to the following manual.
→ FX
Series User's Manual - Hardware Edition
3U
WIRING
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
WIRING
PRECAUTIONS
• When wiring, make sure cutting or wire debris does not enter the ventilation
slits.
Failure to do so may cause fire, equipment failures or malfunctions.
• Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to abnormal data written to the
PLC under the influence of noise:
1) Do not bundle the main circuit line together with or lay it close to the main
circuit, high-voltage line or load line.
Otherwise, noise disturbance and/or surge induction are likely to take
place. As a guideline, lay the control line at least 100mm (3.94") or more
away from the main circuit or high-voltage lines.
2) Ground the shield wire or shield of the shielded cable at one point on the
PLC.
However, do not use common grounding with heavy electrical systems.
• Make sure to properly wire to the European terminal board in accordance
with the following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit,
wire breakage, malfunctions, or damage to the product.
- The disposal size of the cable end should follow the dimensions
described in the manual.
- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires
of unspecified size.
- Affix the electric wires so that neither the terminal block nor the connected
parts are directly stressed.
1) Wire size
To connect to the desired unit, use a shielded twisted pair cable having a
conductor(s) of size AWG22-20.
2) Applicable cable
Type
Wire size
Single-wire
2
2
0.3mm
to 0.5mm
(AWG22 to 20)
2-wire
2 pieces of 0.3mm
2
(AWG22)
3) Termination of cable end
Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it.
An alternative connection is to use a ferrule with insulating sleeve.
Manufacturer
Model
Caulking tool
CRIMPFOX 6
Phoenix Contact Co., Ltd.
AI 0.5-8WH
(or CRIMPFOX 6T-F
*1 Old model name: CRIMPFOX ZA 3
*2 Old model name: CRIMPFOX UD 6
- Strand wire/single wire
- Ferrule with insulation sleeve
Insulation sleeve
Contact area
(Crimp area)
9mm
(0.35")
2.6mm(0.1")
14mm(0.55")
When using a ferrule with insulation sleeve, choose a wire with proper cable
sheath referring to the above outside dimensions, or otherwise, the wire
cannot be inserted easily.
The tightening torque must be 0.22 to 0.25N
m. Do not tighten terminal screws
with a torque outside the above-mentioned range.
Failure to do so may cause equipment failures or malfunctions.
Side
B
1. Outline
FX
-4HSX-ADP high-speed input special adapter (hereinafter called high-speed input
3U
special adapter) is a special adapter dedicated to FX
signals from a rotary encoder of which the output type is a differential line driver to a
high-speed counter or SPD instruction (FNC 56).
Up to two units of this high-speed special adapter can be connected to the main unit
per system. For details on system configuration, refer to the following manual.
→ FX
Series User's Manual - Hardware Edition
3U
1.1 Incorporated Items
Check if the following product and items are included in the package:
Product
FX
-4HSX-ADP high-speed input special adapter
3U
Accessories
Installation manual (This manual)
1.2 Input Allocation and Usable High-Speed Counter Number
When the power is turned on, input numbers of the high-speed input special adapters
are allocated as shown in the table below in the order of unit position to the main unit.
See the table below for usable device number of associated high-speed counter. For
details on high-speed counters, refer to the following manual.
→ FX
Series User's Manual - Hardware Edition
3U
Second unit
High-
High-
Analog
Analog
Analog
speed
speed
special
special
special
input
output
function
function
function
special
special
adapter
adapter
adapter
adapter
adapter
*1 An expansion board is required to use any special adapters other than high-
speed I/O special adapters. For system configuration, refer to the following
manual.
→ FX
Series User's Manual - Hardware Edition
3U
Input number
Associated high-speed counters
C235, C236, C237, C241, C242
First unit X000 to X002, X006
*3
C245
, C246, C247, C249, C251, C252, C254
Second
C 2 38 , C 2 39 , C 2 40 , C 2 43 , C 2 45 (O P ), C 2 48 ,
X003 to X005, X007
unit
C248(OP), C250, C253, C253(OP), C255
*2 Use the terminal of the main unit for reset input if the second high-speed input
may also be
special adapter is not connected.
*3 Use the terminal of the main unit for start input and reset input if the second high-
speed input special adapter is not connected.
Caution
When connecting a high-speed input special adapter, same input numbers are
allocated to the main unit and this special adapter. Must use either one of the
input terminals. If both input terminals are used, assumed action may not be
executed because inputs of the high-speed input special adapter and main unit
are operated in an OR relationship to each other.
• Do not use (wire) the input terminal in main unit corresponding to the input
number used in the high-speed input special adapter.
• Do not use (wire) the input terminal in high-speed input special adapter
corresponding to the input number used in the main unit.
4. Specification
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
* For repair, contact your local Mitsubishi Electric distributor.
• Do not drop the product or exert strong impact to it.
Doing so may cause damage.
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORT AND
STORAGE PRECAUTIONS
• The product is a precision instrument. During transportation, avoid impacts larger
than those specified in the general specifications by using dedicated packaging
boxes and shock-absorbing palettes. Failure to do so may cause failures in the
product. After transportation, verify operation of the product and check for damage
of the mounting part, etc.
4.1 Applicable PLC
Model name
Applicability
FX
3U
Series PLC
Ver. 2.20 (from the first product) and later
The version number can be checked by monitoring D8001 as the last three digits
indicate it.
Note
Cannot be connected to FX
3UC
Series PLC.
4.2 General Specification
For the general specification, refer to the manual of the PLC main unit.
The items other than the following are equivalent to those of the PLC main unit.
→ FX
Series User's Manual - Hardware Edition
3U
Item
Specification
Dielectric
500V AC for one minute
Between input terminal of high-
withstand voltage
speed input special adapter and
Insulation
5MΩ or higher by 500V DC
ground terminal of PLC main unit
resistance
insulation resistance tester
4.3 Power Supply Specification
Item
Specification
Input circuit driving
30mA for 24V DC
power supply
Internally supplied from the main unit service power supply.
Adapter driving
30mA for 5V DC
power supply
5V DC power is supplied internally from the main unit.
*1
*2
)
4.4 Performance Specification
Item
Specification
4 points
Input points
(Not counted among the total I/O points of the PLC.)
Input type
Differential line receiver (Equivalent to AM26C32)
1 phase 1 input
200kHz High-speed counter operated as
Maximum input
1 phase 2 inputs
8mm
frequency
(0.31")
2 phase 2 inputs 100kHz
External cables of input area are insulated from PLC by photo
Insulation
coupler and transformer.
Wiring length
Maximum 10m (32' 9")
*1 The maximum input frequency for the software counter
maximum input frequency of when the main unit counts pulses via the input
terminal. For details on input frequency, refer to the following manual.
→ FX
Series User's Manual - Hardware Edition
3U
*2 It also means the hardware counter is operated as a software counter. For
conditions of a hardware counter which operates as a software counter, refer to
the following manual.
→ FX
Series User's Manual - Hardware Edition
3U
1.3 External Dimensions, Part Names, and Terminal Layout
Series PLC. It retrieves pulse
[4]
3U
[3]
[2]
[1]
7 (0.28")
74 (2.92")
First unit
Special adapter
connector cover [2]
High-
High-
or [5] is removed
speed
speed
Main unit
output
input
special
special
adapter
adapter
Expansion board
*1
Input LED [7]
Input number
Name
First
Second
unit
unit
X0/3
X000
X003
X1/4
X001
X004
X2/5
X002
X005
*2
, C244, C244(OP),
X6/7
X006
X007
[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] High-speed I/O special adapter connector cover:
Remove this cover for connecting high-speed I/O special adapter on the left side.
[3] Name plate
[4] Special adapter slide lock:
Used to connect special adapter on left side of this special adapter.
[5] Special adapter connector cover:
Remove this cover for connecting special adapter on the left side.
[6] Terminal block for inputs (European type):
Connects output signals of differential line driver type.
[7] Input LED (red):
Lit when input turns ON (if input turns ON and OFF alternately at high speed, the
LED flickers fast).
[8] POWER LED (green):
Lit while power is properly supplied from main unit.
[9] Direct mounting hole:2 holes of φ4.5 (0.18") (mounting screw: M4 screw)
[10] Special adapter fixing hook
[11] DIN rail mounting hook
[12] Special adapter connector:
Used to connect the communication special adapter or analog special adapter to
this adapter on left side.
[13] High-speed I/O special adapter connector:
Used to connect the high-speed I/O special adapter to this adapter on left side.
4.5 Connectable Device Caution
*1
The rotary encoder
connected to the input terminal of FX
all of the following conditions;
Item
Output type
Output voltage
*1 If the rotary encoder, which fulfills the above stated conditions, fails to operate,
please confirm specifications in advance.
4.6 Internal Circuit of Input Interface
For connection example and wiring, refer to the following manual.
Rotary encoder etc.
Noninverting
output
Phase A/B/Z
Inverting
output
Phase A/B/Z
0V
*1 X00
indicates input number of the high-speed input special adapter.
*2 SG of the first unit and SG of the second unit are insulated from each other.
Grounding
Grounding should be performed as stated below.
• The grounding resistance should be 100Ω or less.
• Independent grounding should be performed for best results.
When independent grounding is not performed, perform "shared grounding"
of the following figure.
For details, refer to the following manual.
Another
PLC
equipment
Independent grounding
(Best condition)
• The grounding wire size should be AWG 14 (2 mm
• The grounding point should be close to the PLC, and all grounding wire
should be as short as possible.
「电器电子产品有害物质限制使用标识要求」的表示方式
Note: This symbol mark is for China only.
含有有害6物质的名称, 含有量, 含有部品
  本产品中所含有的有害6物质的名称, 含有量, 含有部品如下表所示。
产品中有害物质的名称及含量
hardware counter
*1
部件名称
(Pb)
外壳
可编程
*2
will be the same as the
控制器
印刷基板
×
本表格依据SJ/T 11364的规定编制。
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572
定的限量要求以下。
×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T
26572规定的限量要求。
2. Installation
The product can be mounted on DIN rail (DIN46227) or mounted directly using
[5]
[6]
[9]
[10]
screws.
For installation/uninstallation and safety precautions, refer to the following
manual:
FX -4HSX-ADP
[8]
3U
[7]
POWER
X0/3 X2/5
INSTALLATION
X1/4
X6/7
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
[11]
• Use the product within the generic environment specifications described in
PLC main unit manual (Hardware Edition).
[9]
Never use the product in areas with excessive dust, oily smoke, conductive
15.1 (0.60")
dusts, corrosive gas (salt air, Cl
17.6 (0.70")
15.5 (0.62")
or impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
Terminal layout of [6]
• When drilling screw holes or wiring, make sure that cutting and wiring debris
Input number
do not enter the ventilation slits.
Name
[12]
Failure to do so may cause fire, equipment failures or malfunctions.
First
Second
unit
unit
• Do not touch the conductive parts of the product directly.
X0/3+
X000+
X003+
Doing so may cause device failures or malfunctions.
• Connect the special adapter securely to their designated connectors.
X0/3-
X000-
X003-
Loose connections may cause malfunctions.
X1/4+
X001+
X004+
[13]
X1/4-
X001-
X004-
2.1 Connection to the FX
X2/5+
X002+
X005+
• Refer to the procedure 2) for configuring a new system.
X005-
• Refer to the procedure 1) for adding product to an existing system.
X2/5-
X002-
Procedure
X6/7+
X006+
X007+
1) Turn off the power.
X6/7-
X006-
X007-
Disconnect all the cables connected to the PLC main unit and special adapter.
SG
SG
SG
Dismount the main unit and special adapter mounted on DIN rail or mounted
SG
SG
SG
directly using screws.
2) Install an expansion board to the main unit.
Unit
: mm (inches)
For installation of expansion board, refer to the following manual:
Weight: Approx. 80g (0.18 lbs)
3) Remove the high-speed I/O special adapter
connector cover (Right fig. A) and the special
adapter connector cover (Right fig. B) on the
main unit.
In case of connecting this product to a high-
speed I/O special adapter as an addition,
please replace the 'main unit' in the above
description with a 'special adapter' and
perform the procedure as indicated. (Please
replace the following procedures similarly.)
4) Slide the special adapter slide lock (Right
fig.C) of the main unit.
5) Connect the high-
speed I/O special
adapter (Right fig.D)
to the main unit as
shown on the right.
6) Slide back the
special adapter
slide lock (Right
fig.C) of the main
unit to fix the high-
speed I/O special
adapter (Right
fig.C).
Connection precautions
-4HSX-ADP has to fulfill
3U
Specifications
Differential line driver
5V DC or less
→ FX
Series User's Manual - Hardware Edition
3U
High-speed input special adapter
5V DC
Shielded twisted pair cable
*1
X00 +
*1
330Ω
X00 -
SG
SG
*2
Grounding
(Ground resistance: 100Ω or less)
→ FX
Series User's Manual - Hardware Edition
3U
Another
Another
PLC
PLC
equipment
equipment
Shared grounding
Common grounding
(Good condition)
(Not allowed)
2
) or larger.
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for
有害物质
accidents, and compensation for damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
多溴
and other tasks.
六价铬
多溴联苯
二苯醚
(Hg)
(Cd)
(Cr(VI))
(PBB)
(PBDE)
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
→ FX
Series User's Manual - Hardware Edition
3U
, H
S, SO
or NO
), flammable gas, vibration
2
2
2
2
Series PLC
3U
→ FX
Series User's Manual - Hardware Edition
3U
4)
C
3)
B
A
C
C
D
6)
5)
5)
5)
C
• Install the expansion board to be used before connecting a special adapter.
• Install an expansion board when using a special adapter other than a high-
speed I/O special adapter in combination with a high-speed I/O special
adapter.
• Connect all the high-speed I/O special adapters before connecting other
special adapters when they are used in combination.
Do not connect a high-speed I/O special adapter on the left side of any
special adapters other than other high-speed I/O special adapters.
5V
Equivalent to
AM26C32
For safe use
4)
4)
6)
6)

Advertisement

loading