Security Escort
4.4

Mounting and setting up components

4.4.1

SE coordinator installation

Normally, the enclosures are mounted first with the laying of cables and wires. Then, the
electronics are mounted, wired, and tested.
Notice!
The address of the SE coordinator cannot be configured and is fixed as 0.
4.4.2

SE receiver installation

Mount the electronic assembly to the enclosure. Leave at least 10 cm (4 in.) of wire hanging
out of the unit. Do not leave extra wire inside the enclosure as this could impact the receiving
antennas.
Every SE receiver on each communication bus of the SE coordinator must have its own
address. Set the address on the SE receiver using the dip switches. See the Security Escort
Coordinator & Receiver Installation Manual.
Notice!
Use only address numbers 1 through 15. Do NOT use address number 0 (reserved for SE
coordinator).
Robert Bosch (SEA) Pte Ltd
Mount the enclosure to the mounting surface.
Mount the circuit board to the enclosure.