Test Condition - Acer X110 Service Manual

Acer projector service manual
Hide thumbs Also See for X110:
Table of Contents

Advertisement

4-4 Test Condition

- Circumstance brightness: Dark room less than 2.0 lux.
- Inspection distance: 1.8 m~2.5 m functional inspection.
- Screen size: 60 inches diagonal.
- After repairing each unit, it should be Run-in (refer to the below table).
Symptom
Normal repair
NFF
Auto shutdown
- Get into Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Press power→ left → left → menu on remote controller
Choose Burn In > enter
Lamp On (Min)
Lamp Off (Min)
Set Burning cycle
After setting up the time, choose ''Enter into Burn In Mode'' and press "Menu" button.
Screen Defects (While replacing DMD Chip, DMD Board, Main Board)
< Figure: Zone A, Zone B, Zone C & Frame (as green line) Definition, Active area=Zone A + Zone B >
Frame
X1161/X1261/X1161A/X1161N/X110/H5360
Run-in Time
2 hours
4 hours
6 hours
Press right key to adjust the time (50)
Press right key to adjust the time (10)
Press right key to adjust the cycle
Confidential
4-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H5360X1161X1261Ep720X1161aX1161n

Table of Contents