Samsung SCD80 Service Manual page 161

Hide thumbs Also See for SCD80:
Table of Contents

Advertisement

2. 조정 영문 2001.7.4 2:7 PM 페이지2-4
2-4 Mechanical Check and Adjustment
2-4-1 Tension Regulator Adjustment
2-4-1(A) DISASSEMBLY
1. Refer to 3-2 to remove the Housing Ass' y
2-4-1(B) ADJUSTMENT
1. Set to PB mode (without cassette tape).
2 . Check that the distance between external
surface of Holder Loading and center of
Arm Tension is 0~1㎜. (Fig 2-5 )
3. If necessary, proceed to step 4.
4. If the Arm Tension ❶ is located inside the
position specified, adjust the Band Adjust
Tension ❷ toward arrow A. (If it is located
outside, adjust toward arrow B.)
N o t e: Check if the Arm Tension can be moved
toward arrow C in PB mode.
ARM TENSION ❶
CAP ADJUSTMANT
2-4
2-4-1(C) REASSEMBLY
1. Refer to 3-2 to mount the Housing Ass' y
1±0.3
Fig 2-5
Sumsung Electronics