Startup with 87 Hz characteristic curve............. 37 Operation ......................38 Status of the inverter ................. 38 Service and Error Codes .................. 39 Troubleshooting ..................39 Error memory .................... 39 Error codes ....................40 SEW Electronics Service ................42 Operating Instructions – MOVITRAC® LTE-B...
Page 4
Contents Parameters......................43 Standard parameters ................43 Advanced parameters................44 P-15 Binary input function selection............48 Parameters for monitoring operating data in real time (read only).... 50 Technical Data....................52 Conformity....................52 Information on ambient conditions ............52 Output power and current carrying capacity without filter ......53 Output power and current carrying capacity with filter ......
If you are unclear about any of the information in this documentation, or if you require further information, contact SEW-EURODRIVE. Structure of the safety notes 1.2.1...
You must comply with the information contained in this documentation to ensure safe operation and to achieve the specified product characteristics and performance fea- tures. SEW-EURODRIVE assumes no liability for injury to persons or damage to equip- ment or property resulting from non-observance of these operating instructions. In such cases, any liability for defects is excluded.
The following safety notes are primarily concerned with the use of MOVIPRO units. If you use other SEW components, also refer to the safety notes for the respective com- ponents in the corresponding documentation. Please also observe the supplementary safety notes in the individual chapters of this documentation.
Safety Notes Designated use Any electronic work may only be performed by adequately qualified electricians. Quali- fied electricians in the context of this documentation are persons familiar with electrical installation, startup, troubleshooting and servicing of the product who possess the following qualifications: •...
Safety Notes Installation and assembly Installation and assembly Ensure that the unit is installed and cooled according to the regulations in the related documentation. Protect the unit from excessive strain. Especially during transportation and handling, do not allow the components to be deformed or insulation spaces altered. Prevent mechan- ical damage or destruction of electrical components.
2.10 Inspection and maintenance WARNING Danger of electric shock due to exposed, live parts in the unit. Severe or fatal injuries. • Never open the unit. • Only SEW-EURODRIVE is authorized to carry out repairs. Operating Instructions – MOVITRAC® LTE-B...
3%. In the case of voltage sources with a phase imbalance of more than 3% (as it is common on the Indian subcontinent, in some parts of South-East Asia and China), SEW-EURODRIVE recommends to use input chokes. Operating Instructions – MOVITRAC® LTE-B...
General Specifications Overload capacity Overload capacity ® All MOVITRAC LTE-B products have the following overload capacity: • 150% for 60 seconds • 175% for 2 seconds With an output frequency of < 10 Hz, the overload capacity is reduced to 150% for 7.5 seconds.
Installation General information Installation General information • Before installation, check the inverter carefully to make sure it is not damaged. • Store the inverter in a box until it is used. The inverter must be stored at temperatures between –40 °C and +60 °C and in such a way that it is clean and dry. •...
Page 18
Installation Mechanical installation 4.2.2 Locking IP55/66 units with switching function The main disconnect switch can be locked in "OFF" position using a standard padlock (20 mm). The padlock is not included in the delivery. Press the middle of the switch to insert the padlock. 6328707979 Operating Instructions –...
Page 19
Installation Mechanical installation 4.2.3 IP20 housing: Installation and control cabinet dimensions For applications that require a higher IP protection level than IP20, the inverter must be installed in a control cabinet. Observe the following requirements: • The control cabinet must be made of a heat conductive material unless it has forced cooling.
Page 20
Installation Mechanical installation Dimensions of control cabinet with ventilation openings Control cabinet with ventilation openings Power rating 115 V: 0.37 kW, 0.75 kW Size 1 11.81 9.84 7.87 1.97 230 V: 0.37 kW, 0.75 kW 230 V: 1.5 kW Size 1 15.75 11.81 9.84...
Installation Electrical installation Electrical installation Adhere to the safety information in chapter 2 for installation. WARNING Danger of electric shock. Dangerous voltage levels can still be present inside the unit and at the terminals up to 10 minutes after disconnection from the power supply. Severe or fatal injuries.
Page 22
Installation Electrical installation • Make sure that shieldings and sheaths of power cables are designed according to the wiring diagram in section "Connecting inverter and motor" (page 25). • Make sure that all terminals have been tightened with the proper tightening torques. •...
Page 23
Voltage supply systems with non-grounded star point Operation on voltage supply systems with non-grounded star point (for example IT systems) is also permitted. For this purpose, SEW-EURODRIVE recommends to use an earth-leakage monitor according to the pulse-code measurement principle. Using these devices avoids the earth-leakage monitor from tripping by mistake due to the missing capacitance to ground of the inverter.
Page 24
Installation Electrical installation Connection in the Connection types for motors: star, delta, double star, or star according to NEMA. The motor terminal box nameplate of the motor indicates the nominal voltage for the connection type that has to ® match the operating voltage of the MOVITRAC LTE-B inverter.
Page 25
Installation Electrical installation Connecting • WARNING Danger of electric shock. High voltages can be present when the inverter and motor inverter is not connected properly. Severe or fatal injuries. – It is essential that you adhere to the sequence of connections as depicted below. L2/N not 1-ph.
Page 26
3 frame sizes. The maximum permitted cable length for the group is limited to the values of single con- nection, see chapter "Technical Data" (page 52). For groups with more than 3 motors, SEW-EURODRIVE recommends to use an output choke. 4.3.3...
Page 27
Installation Electrical installation The signal terminal block is equipped with the following signal terminals: Termi- Signal Connection Description nal no. Output +24 V reference Reference voltage for activating DI1 – DI3 +24 V ref out voltage (max. 100 mA) DI 1 Binary input 1 Positive logic "Logic 1"...
Page 28
Installation Electrical installation 4.3.4 Communication socket RJ45 2933413771 Not connected Not connected +24 V Internal bus Internal bus SBus+ SBus– 1) The bit format is defined as follows: 1 start bit, 8 data bits, 1 stop bit, no parity 2) P-12 must be set to 3 or 4 for SBus communication Operating Instructions –...
Page 29
Installation Electrical installation 4.3.5 UL-compliant installation Note the following points for UL-compliant installation: • The inverters can be operated at the following ambient temperatures: IP degree of protection Ambient temperature IP66 / NEMA 4X –10 °C to 40 °C IP55 / NEMA 12 –10 °C to 40 °C IP20 –10 °C to 50 °C...
Page 30
Installation Electrical installation 4.3.6 Electromagnetic compatibility ® The MOVITRAC LTE-B inverter series is designed for use in machines and drive sys- tems. They meet the EMC product standard EN 61800-3 for drives with variable speed. Observe the specifications of Directive 2004/108/EC (EMC) of the Council for EMC compliant installation of the drive system.
Page 31
Installation Electrical installation ® Disabling the EMC IP20 inverters equipped with an EMC filter (such as MOVITRAC LTE-B xxxx xAxx 00 ® filter varistor (IP20) and MOVITRAC LTE-B xxxx xBxx 00) have a higher leakage current to ground than devices without EMC filter. Errors might be signaled on ground indicators when operat- ®...
Startup User interface Startup User interface 5.1.1 Keypad ® Each MOVITRAC LTE-B has an integrated keypad as standard, allowing drive opera- tion and setup without any additional equipment. The keypad consists of 5 keys with the following functions: Function Start / Run •...
Startup Easy startup Easy startup 1. Connect the motor to the drive, checking the connection for the motor voltage rating. 2. Enter rated values given on the nameplate of the motor: • With P-01 and P-02, you set the limit values for minimum and maximum speed. •...
Startup Startup for operation via fieldbus Startup for operation via fieldbus • Start the drive as described in section "Easy startup" (page 33). • Set parameter P-12 to "3" or "4" to control the drive via SBus. • 3 = control word and speed setpoint via SBus, ramp times as defined in P-03 / P-04.
Page 35
Startup Startup for operation via fieldbus DFP 21B FAULT ADDRESS max. 8 2933672203 Bus connection Gateway (e.g. DFx / UOH gateway) Cable to wire Splitter Selection cable Terminating resistor 5.3.1 Permitted cable lengths The permitted total cable length depends on the baud rate set for the SBus: •...
Page 36
Startup Startup for operation via fieldbus 5.3.3 Description of the transferred process data (PD) Process data words (16-bit) from the gateway to the drive (PO): Description Settings Control word Controller inhibit 0: Run 1: Stop Fast stop on 2nd deceleration ramp (P-24) 0: Fast stop 1: Run Stop on process ramp P-03 / P-04 or PO3...
Startup Startup with 87 Hz characteristic curve Example: The following information will be sent to the drive if: • the binary inputs are configured and wired correctly to enable the drive • parameter P-12 is set to 3 to operate the drive via SBus Description Value Description...
Operation Status of the inverter Operation The following information is displayed to being able to check the operating state of the inverter at any time. Status Diplay Inverter OK With inverter not enabled Inverter running With enabled inverter Error / shutdown Error Status of the inverter 6.1.1...
Service and Error Codes Troubleshooting Service and Error Codes Troubleshooting Symptom Cause and solution Overload or overcurrent error of the unloaded Check the star/delta terminal connection in the motor. The nominal operating volt- motor during acceleration age of motor and inverter must match. Delta connection always yields the lower volt- age of a multi-voltage motor.
"U-t" Undertemperature • Occurs at an ambient temperature below - 10 °C. • Increase the temperature to above -10 °C to start the inverter. "th-Flt" Faulty thermistor at heat sink. Please consult SEW-EURODRIVE Service. Operating Instructions – MOVITRAC® LTE-B...
Page 41
SEW-EURODRIVE Service. "EE-F" EEPROM error parameter not EEPROM error parameter not saved, factor settings saved, factor settings restored. restored. If this error occurs again, contact SEW- EURODRIVE Service. "4-20 F" Current at analog input not within • Make sure the input current is within the range defined range.
Service and Error Codes SEW Electronics Service SEW Electronics Service 7.4.1 Sending in product for repair Please contact SEW-EURODRIVE Electronics Service if a malfunction cannot be rectified. Provide the following information when sending the unit in for repair: • Serial number (→ nameplate) •...
Parameters Advanced parameters Parameter Description Value range Factory Explanation setting P-12 Control via Terminal control See section "Easy startup" (page 33). terminals/keypad (terminal Keypad control /SBus control) (only forwards) Keypad control (to toggle between for- wards/backwards, press the <Start> key) SBus network control with internal acceleration/deceler- ation ramps...
Page 46
Parameters Advanced parameters Parameter Description Range Default Explanation P-30 Terminal mode • Edge-r Auto-0 Defines the inverter behavior with reference to the restart function • Auto-0 enable digital input and configures the automatic • Auto-1 to Auto-5 restart function. • Edge-r: The inverter does not start after switching-on or reset if binary input 1 remains closed.
Page 47
Parameters Advanced parameters Parameter Description Range Default Explanation P-35 Scaling factor 0% – 500% 100% Analog input scaling resolution 0.1%. analog input 100% Analog input P-36 Comm. address Address: 0 disabled, 1 – 63 Address: Unique inverter address for communica- tion network.
Parameters P-15 Binary input function selection P-15 Binary input function selection ® The functions of the binary inputs of MOVITRAC LTE-B can be programmed. This means you can select the functions required for your application. The following tables show the functions of the binary inputs depending on the value of parameter P-12 (control via terminals/keypad/SBus) and P-15 (binary input function selection).
Page 49
Parameters P-15 Binary input function selection P-15 Binary input 1 Binary input 2 Binary input 3 Analog input Comments N.O. contact N.C. contact N.O. contact Speed reference Close binary inputs 1 and 3 at the same Briefly closed for for- Briefly opened for stop Briefly closed for back- time to stop the motor...
Parameters Parameters for monitoring operating data in real time (read only) P-15 Binary input 1 Binary input 2 Binary input 3 Analog input Comments Open: Controller Open: Master speed ref- External trip input: No effect Connect external PTC tem- inhibit erence perature sensor or similar to Open: Shutdown...
Page 51
Parameters Parameters for monitoring operating data in real time (read only) Parameter Description Display range Explanation P00 (18) Software ID, I/O and motor e.g. "1.00", "47AE" Version number and checksum. control "1" on the left side indicates the I/O processor. "2"...
Technical Data Conformity Technical Data Conformity All products meet the following international standards: • CE marking according to the low voltage directive • IEC 664-1 Insulation coordination for electrical equipment within low-voltage systems • UL 508C Power conversion equipment • EN 61800-3 Variable-speed electrical drives –...
Technical Data Output power and current carrying capacity without filter Output power and current carrying capacity without filter ® Whether MOVITRAC LTE-B inverters are used with or without filter depends on the regulations applicable in the various countries where the product is used. •...
Page 54
Technical Data Output power and current carrying capacity without filter 9.3.2 1-phase system AC 230 V for 3-phase AC 230 V motors ® MOVITRAC LTE-B – EMC filter class 0 Type MC LTE B... 0004-201-1- 0008-201-1- 0015-201-1- 0015-201-4- 0022-201-4- 0040-201-4- IP20 Part number 08296863...
Page 55
Technical Data Output power and current carrying capacity without filter 9.3.3 3-phase system AC 230 V for 3-phase AC 230 V motors ® MOVITRAC LTE-B – EMC filter class 0 Type MC LTE B... 0004-203-1- 0008-203-1- 0015-203-1- 0015-203-4- 0022-203-4- 0040-203-4- IP20 Part number 08296936...
Page 56
Technical Data Output power and current carrying capacity without filter 9.3.4 3-phase system AC 400 V for 3-phase AC 400 V motors Sizes 1 and 2 ® MOVITRAC LTE-B – EMC filter class 0 Type MC LTE B... 0008-503-1-00 0015-503-1-00 0015-503-4-00 0022-503-4-00 0040-503-4-00...
Page 57
Technical Data Output power and current carrying capacity without filter Size 3 ® MOVITRAC LTE-B – EMC filter class 0 Type MC LTE B... 0055-503-4-00 0075-503-4-00 0110-503-4-00 IP20 Part number 08297045 08297053 08299218 IP55/NEMA-12 Type MC LTE B... 0055-503-4-10 0075-503-4-10 housing without 08297959 08297967...
Technical Data Output power and current carrying capacity with filter Output power and current carrying capacity with filter ® Whether MOVITRAC LTE-B inverters are used with or without filter depends on the regulations applicable in the various countries where the product is used. •...
Page 59
Technical Data Output power and current carrying capacity with filter 9.4.2 3-phase system AC 230 V for 3-phase AC 230 V motors ® MOVITRAC LTE-B – EMC filter class A Type MC LTE B... 0015-2A3-4-00 0022-2A3-4-00 0040-2A3-4-00 IP20 Part number 08297134 08297142 08297150...
Page 60
Technical Data Output power and current carrying capacity with filter 9.4.3 3-phase system AC 400 V for 3-phase AC 400 V motors Sizes 1 and 2 ® MOVITRAC LTE-B – EMC filter class A Type MC LTE 0008-5A3-1-00 0015-5A3-1-00 0015-5A3-4-00 0022-5A3-4-00 0040-5A3-4-00 B...
Page 61
Technical Data Output power and current carrying capacity with filter Size 3 ® MOVITRAC LTE-B – EMC filter class A Type MC LTE B... 0055-5A3-4-00 0075-5A3-4-00 0110-5A3-4-00 IP20 Part number 08297215 08297223 08299196 Type MC LTE B... 0055-5A3-4-10 0075-5A3-4-10 IP55/NEMA-12 housing without switch Part number 08298114...
Page 68
No. 95, Jalan Seroja 39, Taman Johor Jaya Fax +60 7 3541404 Service 81000 Johor Bahru, Johor sales@sew-eurodrive.com.my West Malaysia Mexico Assembly Quéretaro SEW-EURODRIVE MEXICO SA DE CV Tel. +52 442 1030-300 Sales SEM-981118-M93 Fax +52 442 1030-301 Service Tequisquiapan No. 102 http://www.sew-eurodrive.com.mx Parque Industrial Quéretaro scmexico@seweurodrive.com.mx...
Page 69
Fax +92-21-454 7365 mercial Area, seweurodrive@cyber.net.pk Sultan Ahmed Shah Road, Block 7/8, Karachi Peru Assembly Lima SEW DEL PERU MOTORES REDUCTORES Tel. +51 1 3495280 S.A.C. Sales Fax +51 1 3493002 Los Calderos, 120-124 Service http://www.sew-eurodrive.com.pe Urbanizacion Industrial Vulcano, ATE, Lima sewperu@sew-eurodrive.com.pe...
Page 70
0393 Ustanicka 128a Fax +381 11 347 1337 PC Košum, IV sprat office@dipar.rs SRB-11000 Beograd Singapore Assembly Singapore SEW-EURODRIVE PTE. LTD. Tel. +65 68621701 Sales No 9, Tuas Drive 2 Fax +65 68612827 Service Jurong Industrial Estate http://www.sew-eurodrive.com.sg Singapore 638644 sewsingapore@sew-eurodrive.com...
Page 71
Fax +27 13 752-8008 Vintonia robermeyer@sew.co.za P.O.Box 1942 Nelspruit 1200 South Korea Assembly Ansan SEW-EURODRIVE KOREA CO., LTD. Tel. +82 31 492-8051 Sales B 601-4, Banweol Industrial Estate Fax +82 31 492-8056 Service #1048-4, Shingil-Dong, Danwon-Gu, http://www.sew-korea.co.kr Ansan-City, Kyunggi-Do Zip 425-839 master.korea@sew-eurodrive.com...
Page 72
Hayward, CA 94544 cshayward@seweurodrive.com Additional addresses for service in the USA provided on request! Venezuela Assembly Valencia SEW-EURODRIVE Venezuela S.A. Tel. +58 241 832-9804 Sales Av. Norte Sur No. 3, Galpon 84-319 Fax +58 241 838-6275 Service Zona Industrial Municipal Norte http://www.sew-eurodrive.com.ve...
Page 73
Address List Vietnam Sales Ho Chi Minh City All sectors except harbor, steel, coal power Tel. +84 8 8301026 and offshore: Fax +84 8 8392223 Nam Trung Co., Ltd namtrungco@hcm.vnn.vn 250 Binh Duong Avenue, Thu Dau Mot Town, truongtantam@namtrung.com.vn Binh Duong Province khanh-nguyen@namtrung.com.vn HCM office: 91 Tran Minh Quyen Street District 10, Ho Chi Minh City...
Index Index Advanced parameters ..........44 Input voltage ranges ..........11 Ambient conditions..........52 Installation Ambient temperature ..........52 Connecting inverter and motor ......25 electrical............21, 23 mechanical............14 Terminal box connections........24 Conformity..............52 UL compliant............29 Connection Interface, user............32 Safety Notes ............9 IP20 housing Control cabinet with forced cooling Dimensions ............17 Dimensions ............20 IP20 / NEMA-1 housing...
Page 75
Section safety notes..........5 Service .............39, 42 Error codes ............40 UL compliant installation........29 Error memory .............39 Use ................8 SEW Electronics Service ........42 User interface ............32 Troubleshooting ..........39 Signal words in safety notes ........5 Specifications ............11 Voltage ranges, input..........11 Standard parameters ..........43...
Page 80
SEW-EURODRIVE—Driving the world SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 D-76642 Bruchsal/Germany Phone +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com...
Need help?
Do you have a question about the MOVITRAC LTE-B series and is the answer not in the manual?
Questions and answers