Power Supply And Connecting Cable Connection - Toshiba RAS-10PKVPG-E Installation Manual

Hide thumbs Also See for RAS-10PKVPG-E:
Table of Contents

Advertisement

Power Supply and Connecting Cable Connection

Power supply cable
Cord clamp
Screw
Connecting cable
Power supply terminal block (L, N, ˙)
Plastic wire guide
Stripping length of the connecting cable
Earth line
Connecting cable
50 mm
10 mm
3
10 mm
45 mm
Connecting cable
Connecting cable connect
to terminal block (L, N)
Stripping length of the connecting cable
Earth line
50 mm
10 mm
3
10 mm
45 mm
N
L
90 mm
10 mm
Power Supply Input at Indoor Unit Terminal Block (Recommend)
Indoor Unit
Stripping length of the
power supply cable
10 mm
N
L
10 mm
Connecting terminal block
(1, 2, 3, ˙)
Earth line
Connecting cable cord
Power supply cord
Power Supply Input at Outdoor Unit Terminal Block (Optional)
Indoor Unit
Connecting cable connect
to terminal block (3, ˙)
Connecting cable
Earth line
100 mm
90 mm
Terminal block
Connecting cable
3
0
13
Outdoor Unit
Terminal block
Connecting
cable
1 2 3
40
30
Earth line
Connecting cable
Outdoor Unit
Power cord
1 2 3
L N
4
0
3
0
Earth line
Earth line
Connecting cable
Power cord
EN
4
0

Hide quick links:

Advertisement

Table of Contents
loading