Power Supply And Connecting Cable Connection; Power Supply Input Wiring Diagram - Toshiba RAS-B24B2KVG-E Installation Manual

Table of Contents

Advertisement

Connecting cable
Power input at Outdoor Terminal Block
Indoor
Terminal
Block
Outdoor
Terminal
Block
CAUTION
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected fi rmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9. This product can be connected to main power supply.
Connection to fi xed wiring : A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the fi xed wiring.

Power Supply and Connecting Cable Connection

Power Supply Input at Outdoor Unit Terminal Block
Indoor Unit
Connecting cable
connect to 1 2 3
Terminal block (L N 1 2 3)
Earth line
Connecting
cable

Power Supply Input Wiring Diagram

Power input
Stripping length of the
connecting cable
Earth line
50 mm
10 mm
3
2
1
10 mm
70 mm
9
Outdoor Unit
1 2 3
L N
Earth line
Earth line
Connecting cable
Power supply cable

Advertisement