Download Print this page

Meco 72-AUTO Instruction Manual

Digital clamp meter

Advertisement

Quick Links

DIGITAL CLAMP METER
MODEL : 72-AUTO/72T-AUTO
INSTRUCTION MANUAL
1
Range
Accuracy
40A
±(2.5% rdg + 5 dgt)
400A
DC VOLTAGE (Auto Ranging)
Range
Accuracy
600V
±(0.8% rdg + 3 dgt)
AC VOLTAGE (Auto Ranging) 50-60Hz
Range
Accuracy
600V
±(1.2% rdg + 3 dgt)
RESISTANCE (Auto Ranging)
Range
Accuracy
40MV V V V V
±(1.2% rdg + 3 dgt)
Frequency (Auto Ranging)
Range : 10Hz, 100Hz, 1000Hz, 10KHz, 100KHz, 1000KHz, 10MHz
Accuracy : ± (0.5% rdg + 2 dgt)
Sensitivity : Approx 0.7V
Overload Protection : 250V DC / AC rms
Continuity Check
Threshold Level
: 40V Approx.
Response Time
: 1m Sec. Approx.
Open Circuit Voltage : 0.4V Approx.
Indication
: '
' is displayed on LCD and buzzer sounds
at continuity.
3
®
Overload Protection
400A AC Max.
for 1 minute
Overload Protection
600V DC / AC rms
Overload Protection
600V DC / AC rms
Overload Protection
250V DC / AC rms
1. SPECIFICATIONS
1.1 General Specification
Display
3¾ digit liquid crystal display (LCD) with a
n
maximum reading of 4000 counts.
Polarity
Automatic, positive implied, negative polarity
n
indication.
Overrange
(OL) or (-OL) is displayed.
n
Zero
Automatic.
n
Low battery
"
n
indication
voltage drops below the operating level.
Measurement
3 times per second, nominal.
n
rate
Operating
0°C to 50°C at < 70% relative humidity.
n
Environment
Storage
-20°C to 60°C, 0 to 80% R.H. with battery
n
Temperature
removed from meter.
Accuracy
Stated accuracy at 27
n
<75% relative humidity.
Power
Two 1.5V 'AAA' Size Battery
n
Battery life
200 hours typical
n
Dimensions
185 x 65 x 28mm (approx.)
n
Weight
170gms including battery (approx.)
n
Accessories
Pair of test leads x 1, Instruction manual x 1,
n
1.5V batterys (installed) x 2,
Carring Case x 1, (K type thermocouple upto
260
Maximum Jaw
25mm
n
Opening
Diode Test
Measurement Current : 1.0 ± 0.6 mA Approx.
Open Circuit Voltage
: 1.6V Approx.
Capacitance (Auto Ranging) (72T-AUTO only)
Range
: 5nF, 50nF, 500nF, 5
Accuracy
: ± (3% rdg + 2 dgts)
Overload Protection : 250V DC / AC rms
Temperature (72T-AUTO only)
Range
: -20
0
Accuracy
: ± (3% rdg + 5 dgts)
Resolution
: 1
0
C
Sensor
: K type thermocouple
72-72T : 28-09-2012
" is displayed when the battery
0
C ± 5
0
C,
C for 72T-AUTO only) x 1
0
F, 50
F, 200
m
m
C to 750
0
C
2
F.
m

Advertisement

loading

Summary of Contents for Meco 72-AUTO

  • Page 1 1.1 General Specification Display 3¾ digit liquid crystal display (LCD) with a DIGITAL CLAMP METER maximum reading of 4000 counts. Polarity Automatic, positive implied, negative polarity MODEL : 72-AUTO/72T-AUTO indication. Overrange (OL) or (-OL) is displayed. Zero Automatic. Low battery “...
  • Page 2 “COM” jack. NOTE : Use “REL” button to enter the relative mode, the “REL” a) Set Range switch to the V range (72-AUTO) annunciator turn on, zero the display and store the displayed reading as b) Set Range switch to the V / (72T-AUTO) a referance value.
  • Page 3 National Standards. 2. This Clamp Meter is designed to take current measurements on circuits with a maximum voltage difference of 500VAC MECO METERS PVT. LTD. between any conductor and ground potential. Using the instrument for current measurements on circuits above this Plot No.

This manual is also suitable for: