3. MAINTENANCE
WARNING : Remove test leads before changing battery or servicing.
Battery Replacement
Power is supplied by two 1.5V 'AAA' size battery or Equivalent.
The "
" appears on the LCD display when replacement is needed, To
replace the battery, remove the screw from the battery cover and lift off
the battery cover. Remove the batterys & repleced with new batterys.
4. SAFETY INFORMATION
The following safety information must be observed to ensure maximum
personal safety during the operation of this meter:
1. Do not use the meter if the meter or test leads look damaged,
or if you suspect that the meter is not operating properly.
2. This Clamp Meter is designed to take current measurements
on circuits with a maximum voltage difference of 500VAC
between any conductor and ground potential. Using the
instrument for current measurements on circuits above this
voltage may cause electric shock, instrument damage or
damage to the equipment under test.
Before measuring current make certain the test leads are
removed from the instrument.
3. The instrument is protected for overload upto 600 VAC for 1
minute. Do not take current readings on circuits where the
maximum current potential is not known.
Do not exceed the maximum currents that this instrument is
designed to measure.
4. Turn off power to the circuit under test before cutting,
unsoldering, or breaking the circuit. Small amounts of current
can be dangerous.
5. Use caution when working above 60V DC or 30V AC rms.
Such voltages pose a shock hazard.
6. When using the probes, keep your fingers behind the finger
guards on the probes.
7. Measuring voltage which exceeds the limits of the clamp meter
may damage the meter and expose the operator to a shock
hazard. Always recognize the meter voltage limits as stated
on the front of the meter.
Certificate of Calibration
We hereby certify that this product has been calibrated and found
to be in accordance with the applicable SPECIFICATIONS and
STANDARDS.
Accuracies of the standard equipment used in this calibration
are traceable to the National Standards.
MECO METERS PVT. LTD.
Plot No. EL-60, MIDC Electronic Zone, TTC Industrial Area,
Mahape, Navi Mumbai - 400710 (INDIA)
Tel : 0091-22-27673311-16, 27673300 (Board)
Fax : 0091-22-27673310, 27673330
E-mail : sales@mecoinst.com
Web : www.mecoinst.com
SR. NO.
:
CHECKED BY :
DATE
:
MODEL NO.
:
72-72T : 28-09-2012
®

Advertisement

loading

This manual is also suitable for:

72t-auto