Bus-Bar upto
16mm x 65mm
Cable upto
43mm Diameter
1
1.2 Electrical Specification
Accuracies are ± (% reading + number of digits) at 27 ± 5°C and
humidity of less than 75% RH.
AC CURRENT (50-60Hz)
Range
Accuracy
40A
±(3% + 4dgt)
400A / 1000A
±(2% + 4dgt)
DC VOLTAGE (Auto Ranging)
Ranges
: 4V, 40V, 400V, 1000V
Accuracy
: ± (0.5% rdg + 4 dgt) on 4V
± (0.7% rdg + 4 dgt) on 40V & 400V
± (1% of rdg + 4 dgt) on 1000V
Resolution
: 1mV to 1V
Input Impedance
: 10MV on all ranges except,
11MV on 4V
Overload Protection : 1200V DC/800V AC
AC VOLTAGE (Auto Ranging) 40-500Hz
Range
: 4V, 40V, 400V, 750V
Accuracy
: ± (1.0% rdg + 8 dgt) on all ranges except,
± (1.5% rdg + 8 dgt) on 750V
Resolution
: 1mV to 1V
Input Impedance
: 10MV on all ranges except, 11MV on 4V
Overload Protection : 1200V DC/800V AC
RESISTANCE (Auto Ranging)
Range
: 400V, 4KV, 40KV, 400KV, 4MV, 40MV
Accuracy
: ± (0.7% rdg + 4 dgt) on all ranges except
± (1.2% of rdg + 4 dgt) on 4MV
± (2.5% of rdg + 4 dgt) on 40MV
3
DIGITAL
CLAMP
METER
MODEL : DT3150
INSTRUCTION
MANUAL
Overload Protection
1000A AC Max.
for 1 minute
®
1. SPECIFICATIONS
1.1 General Specification
Display
n
Polarity
n
Overrange
n
Zero
n
Low battery
n
indication
Measurement
n
rate
Operating
n
Environment
Storage
n
Temperature
Power
n
Battery life
n
Dimensions
n
Weight
n
Accessories
n
Maximum Jaw
n
Opening
Resolution
Test Current
Overload Protection : 500V DC/AC
Continuity Check
Threshold Level
Response Time
Open Circuit Voltage
Indication
Overload Protection
Diode Test
Measurement Current : 1.0 ± 0.6 mA Approx.
Open Circuit Voltage
Overload Protection
Frequency (Auto Ranging)
Range
Accuracy
Sensitivity
Overvoltage Protection : 200V DC or AC peak
% Duty Cycle (Auto Ranging)
Range
Accuracy
Resolution
Overvoltage Protection : 200V DC or AC peak
Capacitance (Auto Ranging)
Range
Accuracy
Resolution
3¾ digit liquid crystal display (LCD) with a
maximum reading of 3999.
Automatic, positive implied, negative polarity
indication.
(OL) or (-OL) is displayed.
Automatic.
"
" is displayed when the battery
voltage drops below the operating level.
3 times per second, nominal.
0°C to 50°C at < 70% relative humidity.
-20°C to 60°C, 0 to 80% R.H. with battery
removed from meter.
Two 1.5V 'AAA' Size Battery
200 hours typical
247mm (H) X 76mm (W) X 39mm (D)
465 grams approx.
One pair of test leads, instruction manual,
1.5V batterys (installed), Carring Case,
Can measure round cables upto 43mm
dia & Flats (Bus Bar) 65mm x 16mm
: 0.1V to 0.01MV
: 0.7mA on 400V, 0.1mA on 4KV,
30µA on 40KV, 4µA on 400KV
: 40V Approx.
: 1m Sec. Approx.
: 0.4V Approx.
: '
' is displayed on LCD and buzzer sounds
at continuity.
: 500V DC / AC
: 0.4V Approx.
: 500V DC / AC
: 10.00Hz, 50.00Hz, 500.0Hz, 5.000kHz,
50.00kHz, 500.0kHz
: ± (0.5% rdg + 2 dgt)
: 3V
: 1% to 90%
: ± (0.5% rdg + 5 dgt)
: 0.1%
: 40nf, 400nf, 4mf, 40mf, 100mf
: ± (5% rdg + 10 dgt)
: 0.01nf to 0.1mf
2
4

Advertisement

loading

Summary of Contents for Meco DT3150

  • Page 1 1.5V batterys (installed), Carring Case, METER Maximum Jaw Can measure round cables upto 43mm Opening dia & Flats (Bus Bar) 65mm x 16mm MODEL : DT3150 INSTRUCTION MANUAL 1.2 Electrical Specification Resolution : 0.1V to 0.01MV Accuracies are ± (% reading + number of digits) at 27 ± 5°C and Test Current : 0.7mA on 400V, 0.1mA on 4KV,...
  • Page 2 2.2 Voltage Measurements 2. OPERATION Connect the red test lead to the “VV” jack and the black test lead Before taking any measurements, read the safety information section. to the “COM” jack. Always examine the instrument for damage, contamination (excessive Set the Function/Range switch to the desired Voltage type dirt, grease, etc.) and defects.