The illustrations provide the overall
size and finished cut-out dimensions
that you need to plan for in your
installation.
IMPORTANT NOTE: When multiple
15" (381) cooktop modules are
installed side by side, refer to the
countertop cut-out dimensions on
page 35.
For the 15" (381) gas multi-function
cooktop, the gas service may be
supplied through the floor or within
the shaded area shown in the illustra-
tion. Refer to the illustration for
specifics on cut-out dimensions and
placement of gas and electrical.
This cooktop can accommodate the
Wolf downdraft system, a Wolf
chimney or Pro Series hood. When
installing a ventilation hood, refer to
the specific requirements of the hood
for the minimum dimension to
cooking surface. Refer to pages 60-82
for ventilation specifics.
Electrical and Gas Requirements
The electric ignition system is a safe,
convenient and reliable manner to
provide ignition for the burner. The
Wolf gas multi-function cooktop
requires a separate 120V, 60 Hz
power supply. The service should
have its own 15 amp circuit breaker,
and a grounded 3-prong receptacle
should be located within the reach of
the 6' (1.8 m) power cord.
IMPORTANT NOTE: A ground fault
circuit interrupter (GFCI) is not
recommended and may cause inter-
ruption of operation.
Locate electrical and gas supply
within the shaded area shown in the
illustration.
Dimensions in parentheses are in millimeters unless otherwise specified.
C
O O K T O P S
The gas multi-function cooktop is
designed to operate on natural gas at
5" WC (water column) pressure or LP
gas at 10" (254) WC pressure. It is
supplied with a 1/2" NPT female gas
connection at the right rear corner of
the cooktop.
The Wolf gas multi-function cooktop
functions up to 8000' (2438 m) in
altitude without any adjustment. If
installation is above 8000' (2438 m),
contact your Wolf dealer.
13"
(330)
1
19
/
"
4
(489)
1
2
/
COOKTOP CUT-OUT
2
DEPTH
(64)
36"
STANDARD
FLOOR TO
COUNTER
LOCATION OF GAS
SUPPLY MAY ALSO
EXTEND 5" ON FLOOR
FROM BACK WALL
5"
(127)
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side.
* Minimum 24" (610) from protected cabinet or 30" (762) from unprotected cabinet to cooking surface.
** Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above cooking surface.
Cut-out dimensions and electrical placement for gas multi-function cooktop.
You must follow all National Electrical
Code regulations. In addition, be
aware of local codes and ordinances
when installing your service.
This cooktop is intended for
indoor use.
24"
30"*
OR
(610 or 762)
18"
TO COOKING
(457)
SURFACE
"
min
7"**
(178)
E
(914)
HEIGHT
LOCATION OF GAS SUPPLY
COOKTOP
1
2
/
"
2
min
(64)
WARNING
30"
(762)
33"
(838)
RECOMMENDED
CABINET WIDTH
18"
14"
(356)
(457)
CUT-OUT
7"**
WIDTH
(178)
5"
(127)
G
15"
(381)
15"
(381)
MAY ALSO EXTEND 5" ON
FLOOR FROM BACK WALL
14"
(356)
CUT-OUT
WIDTH
1
19
/
"
4
(489)
COOKTOP
CUT-OUT DEPTH
FRONT OF COUNTERTOP
43