Mitsubishi Electric MELSEC-Q64DA Reference Manual page 23

Digital-analog converter module
Table of Contents

Advertisement

Item
Relevant manual
Error codes
Error code list
Error code
None
Labels
Input labels
Name (Comment)
Label name
Execution
FB_EN
command
Module start XY
i_Start_IO_No
address
Output labels
Name (Comment)
Label name
Execution status
FB_ENO
Completed without
FB_OK
error
Error flag
FB_ERROR
Error code
ERROR_ID
Description
•Digital-Analog Converter Module User's Manual
•QCPU User's Manual (Hardware Design, Maintenance and Inspection)
•GX Works2 Version 1 Operating Manual (Common)
•GX Works2 Version 1 Operating Manual (Simple Project, Function Block)
Description
No errors are stored for this FB.
Data
type
Bit
Word
Data
type
Bit
Bit
Bit
Word
MELSEC-Q Digital-Analog Converter Module FB Library Reference Manual
Setting range
ON, OFF
Depends on the I/O point
range. For details, refer to
the CPU user's manual.
Initial
Description
value
OFF
ON: Execution command is ON.
OFF: Execution command is OFF.
OFF
When ON, it indicates that the enabled operation of
each setting is completed.
OFF
When ON, it indicates that an error has occurred.
0
FB error code output.
23/49
Description
ON: The FB is activated.
OFF: The FB is not activated.
Specify the starting XY
address (in hexadecimal)
where the Q64DA module is
mounted. (For example, enter
H10 for X10.)
FBM-M042-B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q64dan

Table of Contents