General Information - Honeywell RAEGuard 2 PID User Manual

Table of Contents

Advertisement

1

General Information

The RAEGuard 2 PID is a fixed photoionization detector (PID) that
measures a broad range of volatile organic compounds (VOCs). It
operates on 10 to 28 VDC and provides an analog (4-20mA) three-
wire signal output, and RS-485 Modbus digital signal output.
RAEGuard 2 PID uses an intelligent processing platform and digital
sensor technology, supports multiple ranges and resolutions, and can
perform off-line calibration and environmental self-adaptation.
RAEGuard 2 PID has a graphic display and local sound alarm and
light status indicator. A magnetic key interface enables the detector to
be calibrated and operational parameters adjusted with the explosion-
proof enclosure in place. In addition, the PID module can be easily
removed in hazardous locations for calibration or maintenance.
Key features:
Digital Smart Sensor Technology
Three wires, supports 4-20mA analog output
Operates in flow-through mode and can be used in most
environments
RS-485 digital communication in ModBus protocol
Explosion-proof stainless-steel enclosure for hazardous
environment applications
Magnetic-key interface eliminates the need to open the explosion-
proof housing when adjusting parameters.
Matrix LCD of 128x64 supports graphic display
LED alarms when High or Low alarm point is reached
Operation at 10 to 28 VDC
Three dry contacts (<30V, 2A) normally open (or normally closed),
one for High and Low alarm, another for Fault alarm
RAEGuard 2 PID User's Guide
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents