Panasonic EB-GD35 Service Manual page 38

Gsm personal cellular phone
Table of Contents

Advertisement

EB-GD35 EB-GD35C
Calibration of output power on each power level
NOTE: To ensure that the telephone operates within set SAR margins, Panasonic recommends that a power meter capable
of measurement to an accuracy of ±0.2 dB is used when calibrating power levels. Use of a less accurate power meter
may result in the telephone failing to meet SAR standards.
1.
Power on the telephone in Test Set Mode.
2.
Scroll down the menu until CHANGE CH <62> is highlighted and then press ENTER.
3.
Scroll down the menu until PL <5> is highlighted. Use the left and right cursor keys to select <14>. Press ENTER.
4.
Scroll down the menu until TX DATA <OFF> is highlighted. Using the left / right cursor keys, highlight <NRL 1> and press
ENTER.
5.
The channel box screen should appear as shown below.
6.
If measured power is in the range of the target power, then proceed to step 10.
7.
At the Channel box, press F7 to view the TRIM for the mid-channel.
http://cxema.ru
Figure 6.8: Software Screen 2
Figure 6.9: Power level view 1
38