Raymarine RAY90 Installation & Operation Instructions page 70

Table of Contents

Advertisement

Product does not turn on or keeps turning off
Possible causes
Blown fuse / tripped breaker
Poor / damaged / insecure power supply cable /
connections
Incorrect power connection
Power source insufficient
Raymic Handset will not power up
Possible causes
Handset not turned on
Software Base station / Handset mismatch
Poor / damaged / insecure cables / connections
70
Possible solutions
1.
Check condition of relevant fuses and breakers and connections, replace if necessary (Refer to
Technical specification
for fuse ratings.)
2. If fuse keeps blowing check for cable damage, broken connector pins or incorrect wiring.
1.
Check that the power cable connector is fully inserted into the unit and locked in position.
2. Check the power supply cable and connectors for signs of damage or corrosion, replace if necessary.
3. With the unit turned on, try flexing the power cable near to the display connector to see if this causes the unit to
re-boot/loose power, replace if necessary.
4. Check the vessel's battery voltage, the condition of the battery terminals and power supply cables, ensuring
connections are secure, clean and free from corrosion, replace if necessary.
5. With the product under load, using a multi-meter, check for high voltage drop across all connectors/fuses
etc, replace if necessary.
The power supply may be wired incorrectly, ensure the installation instructions have been followed. (Refer to
4 Cables and connections
for cable and connection requirements.)
With the product under load, using a multi-meter, check the power supply voltage as close to the unit as possible
to establish actual voltage when the current is flowing. (Refer to
supply requirements.)
Possible solutions
The Raymic handset is compatible with the Ray60, Ray70, Ray90 and Ray91 radios. The Raymic handset is powered
separately from the Base station. Press the Power button located on the top of the Handset to power it on.
The Raymic handset and Base station must both be running compatible software, refer to the
Handset software compatibility
section for details of compatible software versions.
1.
Check that the Base station is correctly powered.
2. With the Handset turned on, try flexing the cable near to the connectors to see if this causes the Handset to
re-boot/loose power, replace if necessary.
3. Check cable connections are secure, clean and free from corrosion, replace if necessary.
Chapter 12
Chapter 12 Technical specification
for power
Base station and
Chapter

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ray91

Table of Contents