Download Print this page

Bellman & Symfon VISIT BE1551 User Manual

Visit series
Hide thumbs Also See for VISIT BE1551:

Advertisement

Quick Links

VISIT TRANSMITTERS
Visit smoke alarm
Overview
Signal horn
Test button
Front cover
2 x screw holes

Technical specifications

In the box
Size and weight
BE1551 Visit smoke alarm
Height: 118 mm, 4.6"
1 x 9 V alkaline battery
Width: 140 mm, 5.5"
2 x screws and plugs
Depth: 42 mm, 1.6"
User manual
Weight: 200 g, 7 oz. incl. battery
Power and battery
Sensor type
Battery type
Ionization smoke detection
Duracell MN1604
9 V alkaline battery
Audible alarm
Power consumption
Min 85 dB(A) @ 3m (10'), 2.6 kHz
Idle position < 15 μA
Activation
Battery life
Minimum 3 years
Via the test button
Via the built-in smoke detector
1
Radio LED
Battery
Radio button
Status LED
Frequency and coverage
Radio frequency
868.30 MHz
Coverage: Up to 200 m (218 yd.), clear
line of sight. It depends on the building's
characteristics and radio conditions.
Environment
For indoor use only
Operating temperature
4° till 40° C, 39° to 104° F
Relative humidity
15% to 95% RH, non-condensing
Smoke sensitivity
Meets the BS EN 14604:2005 standard
Setting up the smoke alarm
1
Remove the front cover by rotating it fully backwards and connect the battery to the battery snaps to start the unit.
The alarm will chirp during startup.
2
Mark the location of the screw holes and fix the smoke alarm to the ceiling using the supplied screws and plugs. Mount
it at least 30 cm, (12") from walls and other obstructions, see Location and positioning below.
3
Put the cover back on the smoke alarm by pressing gently until it snaps into place.
1
Location and positioning
Sensor
Fit the smoke alarms in the center of the ceiling outside
the bedrooms, at least 30 cm from any wall. If the
bedrooms are in different areas of the house, separate
smoke alarms are recommended. In multi-storey
properties, install at least one smoke alarm on each floor.
Avoid kitchens, fireplaces or garages, as cooking
fumes and car exhaust may cause false alarms. The
smoke alarm should not be installed in damp spaces,
close to fans, etc. or in agricultural buildings.
= Minimum
= Additional
BE1551
2
3
Testing the connection
1
Press and hold the smoke alarm test button until the alarm
sounds. The smoke alarm transmits a radio signal to the
receiver.
2
The red Visit LED on the receiver lights up to show that the
signal was received. In addition, it starts to sound, flash or
vibrate depending on the receiver.
Please note: The smoke alarm will stop sounding shortly after
the button is released and the receiver will time out within 40s.
1
2
2

Advertisement

loading

Summary of Contents for Bellman & Symfon VISIT BE1551

  • Page 1: Technical Specifications

    VISIT TRANSMITTERS Visit smoke alarm BE1551 Overview Setting up the smoke alarm Signal horn Test button Radio LED Remove the front cover by rotating it fully backwards and connect the battery to the battery snaps to start the unit. The alarm will chirp during startup. Mark the location of the screw holes and fix the smoke alarm to the ceiling using the supplied screws and plugs.
  • Page 2: Troubleshooting

    VISIT TRANSMITTERS Visit smoke alarm BE1551 Signal pattern Changing the radio key The smoke alarm LED blinks in red once per minute to show that it is working correctly. If your Visit system is activated for no reason, there is probably a nearby system that triggers yours. In order to avoid radio Depending on the alarm, the signal patterns are as follows: interference, you need to change the radio key on all units.