FAN
JUNCTION BOX DETAIL
FIGURE 11
2.4

FAN OPERATION

The accessory fan is wired in series with a speed con-
trol switch and a temperature sensor switch. Set the
speed control to an "ON" position and light the heater.
The temperature sensor switch will automatically start
the fan when the switch warms up—and stop the fan
when it cools down. You can manually stop the fan by
turning the speed control switch to "OFF". See Figure
11 for fan wiring diagram.
3.0

SERVICING AND MAINTENANCE

A. HEATER SERVICING: Frequency of heater servic-
ing will depend upon use and type of installation.
B. IMPORTANT: TURN OFF GAS BEFORE SERVIC-
ING APPLIANCE. IT IS RECOMMENDED THAT A
COMPETENT SERVICE TECHNICIAN PERFORM
SERVICE CHECK-UPS AT THE BEGINNING OF
EACH HEATING SEASON.
18
BLK
BLK
TEMP. SENSOR
SWITCH
JUNCTION BOX
YELLOW/GRN
GRD
Heat & Glo • ATS-AU-D • 327-900 Rev. D • 2/06
JUNCTION BOX
TEMPERATURE
SENSOR SWITCH
FAN SPEED
CONTROL
SPEED CONTROL
FAN WIRING DIAGRAM
BLK
BLK
BLK
BLK
BLUE
BRN
YELLOW/GRN
C. The appliance and flue system should be inspected
before initial use and at least annually by a quali-
fied field service person.
D. Inspect the external flue cap on a regular basis to
make sure that no debris is interfering with the air
flow.
E. Keep the control compartment, logs, and burner
area surround the logs clean by vacuuming or brush-
ing at least twice a year.
CAUTION:
ONLY WHEN COOL.
BLUE
BLUE
BRN
BROWN
YW/GR
YELLOW/GREEN