Troubleshooting; Fcc Compliance; Specifications - GE SuperBus 2000 Installation Instructions

2-amp power supply

Advertisement

4
SuperBus 2000 2-Amp Power Supply
Installation Instructions

Troubleshooting

Problem
Green LED is off
Red LED is off.
System touchpads display AUX
POWER FAIL.
System touchpads display AUX
POWER BATT trouble.
System touchpads display AUX
AC POWER trouble.
Trademark/disclaimer
SuperBus is a registered trademark of GE Security. Concord is a trademark of GE
Security. All other trademarks are property of their owners.
Action
1. Check that power supply transformer is
plugged into outlet.
2. Check that transformer is not plugged into
an outlet controlled by a switch.
3. Check outlet circuit breaker/fuse. Reset/
replace as needed.
Check/correct bus (A & B) wiring connections
at module and panel.
1. Check for shorts on wire connected to
power supply +12V OUT terminal.
2. Verify that devices connected to power
supply +12V OUT terminal are not drawing
more than 2 amps.
1. Check that power supply battery is
connected.
2. Power supply battery needs charging.
Battery may need at least 4 hours to fully
charge.
1. Check that power supply transformer is
plugged into outlet.
2. Check that power supply transformer is
not plugged into an outlet controlled by a
switch.
3. Check outlet circuit breaker/fuse. Reset/
replace as needed.
GE Security
1275 Red Fox Road
Arden Hills, MN 55112

FCC compliance

This device complies with FCC Rules Part 15. Operation is subject to the
following two conditions.
This device may not cause harmful interference.
This device must accept any interference that may be received, including inter-
ference that may cause undesired operation.
Changes or modifications not expressly approved by GE Security can void the
user's authority to operate the equipment.

Specifications

Panel compatibility
Power input required
Power output
Battery type
Recommended Battery Manu-
facturer
Maximum load for UL installa-
tions
Operating temperature
Storage temperature
Max. relative humidity
Dimensions (LxWxD)
UL
cUL
Technical Support
T: 800.gesecurity
F: xxx.xxx.xxxx
www.gesecurity.com
Concord 4 series control panels
24 VAC, 50 VA class II power transformer
9 to 14 VDC, 2.0 amps maximum, current
limited
12V, 4.5Ah or 7Ah lead acid
Portalac Model # PE12V7 (7Ah), PE12V4.5 (4.5
Ah)
95 mA (4.5Ah battery), 190 mA (7 Ah battery)
°
°
°
°
32
to 120
F (0
to 49
C)
°
°
°
°
-30
to 140
F (-34
to 60
C)
85%, non-condensing
5.125 in. x 7.85 in. x 1.0 in. (13 cm x 20 cm x
2.5 cm)
985, 1023, and 1610
C1023-1974, S545-M89