Ordering Information – 7SG1123 Argus
Product description
Directional O/C relay
Ideal for directional overcurrent
and earth fault protection of solid
ring systems utilising the fully
independent bi-directional
feature.
)
High burden 110V & 220V binary inputs compliant with ESI48-4 ESI 1 available via external dropper resistors with 48V binary input version
1
for 5 binary inputs and 110 V application, order resistor box VCE:2512H10065 in addition
for 9 binary inputs and 110 V application, order resistor box VCE:2512H10064 in addition
for 5 binary inputs and 220 V application, order resistor box VCE:2512H10067 in addition
for 9 binary inputs and 220 V application, order two resistor boxes VCE:2512H10067 in addition
Refer to website for application note about ESI48-4 compliance
Siemens Protection Devices Limited
Variants
Number of elements
Three pole relay
Auxiliary supply/binary input voltage
24/30/48 V DC auxiliary, 30 V binary input
110/220 V DC auxiliary, 30 V binary input
24/30/48 V DC auxiliary, 48 V binary input
110/220 V DC auxiliary, 48 V binary input 1)
110/220 V DC auxiliary, 110 V low burden binary input
110/220 V DC auxiliary, 220 V low burden binary input
Type of elements
3 pole phase-fault directional
2 pole phase-fault directional and sensitive/restricted
earth-fault (SEF/REF)
2 pole phase-fault directional and earth-fault directional or 2 pole
phase-fault directional and earth-fault
2 pole phase-fault directional and earth-fault directional or
2 pole phase-fault directional and earth-fault
2 pole phase-fault and earth-fault directional
2 pole phase-fault and earth-fault directional
Nominal current
1/ 5 A
I/O range
5 Binary Inputs / 11 Binary Outputs (incl. 3 changeover)
9 Binary Inputs / 7 Binary Outputs (incl. 3 changeover)
Communication interface
Fibre optic (ST-connector) / IEC 60870-5-103 or Modbus RTU
RS485 interface / IEC 60870-5-103 or Modbus RTU
Directional measurement characteristic angle (CA)
+30º, +45º for phase faults
0º, -15º, -45º, -65º for earth faults
0º, -15º, -45º, -90º for earth faults
+30º, +45º for phase faults and 0º, -15º, -45º, -65º for earth faults
+30º, +45º for phase faults and 0º, -15º, -45º, -90º for earth faults
Housing size
Case size E6 (4U high)
Case size E8 (4U high)
Order No.
□ □ □ □ □
7 S G 1 1 2
-
▲ ▲ ▲ ▲ ▲
|
| | | | |
|
| | | | |
|
| | | | |
| | | | |
3
| | | | |
| | | | |
| | | |
0
| | | |
1
| | | |
2
| | | |
3
| | | |
4
| | | |
5
| | | |
| | | |
| | |
J
|
|
K
|
|
|
|
L
|
|
|
|
L
|
|
| | |
M
| | |
M
| | |
| | |
| |
A
| |
| |
1
2
□ □
-
A 0
▲ ▲
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
1 E
|
1 E
|
|
4 E
|
|
5 E
|
2 D
3 D
| |
| |
| |
| |
| |
|
| |
|
| |
|
| |
|
| |
| |
1
| |
2
| |
| |
|
1
|
2
|
3
|
4
|
5
|
|
D
E
16