Circuit
Frequency Coverage
Plate Input
Plate voltage
Drive Requirement
Input Impedance
Output Impedance
Third Order Distortion
Tube Complement
Cooling
Power Requirements
Dimensions
Weight
POWER - OFF
OPER - TUNE.
SWR - IP
F - R
SENS
PLATE
The FL-2000B has been designed incorporating two safety locks to prevent
dangerous high voltage shock. However, extreme care is recommended when
servicing inside the cabinet
SPECIFICATIONS
: Grounded Grid Class B
: Ham bands 80 through 10 meters
: 1200 Watts PEP, 1000 Watts CW and 600 Watts AM
: 2400 Volts DC
: 100 Watts PEP
: 50 ohms, unbalanced
: 50 - 75 ohms, unbalanced
: 30 db or better at 1000 Watts PEP
: 2 x 572B/T160
: Forced-air cooling
: AC 100,
1 10 Volts 50/60Hz 17 Amps
AC 200, 220, 230 Volts 50/60Hz 9 Amps
1/2
: 14
" Wide, 6
: 44 Ibs
FRONT PANEL CONTROLS
: Rocker switch turns power on
: Rocker switch applies Bias when standby and relay
is disengaged.
: Rocker switch selects either SWR or plate current
meter reading.
: Rocker switch selects either forward or reflected
SWR bridge reading.
: Potentiometer
measurement.
: Plate capacitor in tank circuit.
INSTALLATION
.
- 2 –
1/4
1/2
" High,
11
" Deep
adjusts
meter sensitivity for SWR
Amateur Radio Directory
Downloaded by